Real-time dosimeter based on LiF: Mg, Cu, P and SiPM

K Tang, S Zhang - Radiation Measurements, 2021 - Elsevier
The dose characteristics of LiF: Mg, Cu, P, using RL, weren't reported up to now. The first
investigation into the use of a SiPM directly coupled to a LiF: Mg, Cu, P detector as a real …

[HTML][HTML] A new dead-time determination method for gamma-ray detectors using attenuation law

T Akyurek - Nuclear Engineering and Technology, 2021 - Elsevier
This study presents a new dead-time measurement method using the gamma attenuation
law and generalized dead-time models for nuclear gamma-ray detectors. The dead-time of …

Simultaneous experimental evaluation of pulse shape and deadtime phenomenon of GM detector

B Almutairi, S Alam, CS Goodwin, S Usman… - Scientific reports, 2021 - nature.com
Abstract Analysis of several pulse shape properties generated by a Geiger Mueller (GM)
detector and its dependence on applied voltage was performed. The two-source method …

Study of dead time estimation method based on pulse interval distribution

J Liu, X Hong, H Huang, X Song, L Li, C Zhou - Applied Radiation and …, 2024 - Elsevier
In nuclear radiation detection, some measured radiation counts are lost due to dead time.
Estimation of dead time is necessary to restore the counting information in quantitative …

Measuring the Dead Time of a Geiger Counter

F Riggi - Educational and Amateur Geiger Counter Experiments …, 2024 - Springer
Because of the time distribution of random events, it is possible that two events are very
close in time, so that the second event is lost by the detector, due to its dead time. This …

Detector integration of severe accident management instrumentation for robotic applications at nuclear reactor facilities

O Nusrat - 2021 - library-archives.canada.ca
In the aftermath of a nuclear accident, robots can be used to monitor and assess radiological
contamination, preventing harmful exposure to plant personnel. In this work, several …

Development of a Modular Radiometric Measurement System for Radiation Protection

A Litvakas - 2023 - epubl.ktu.edu
Abstract [eng] In this research a modular radiometric measurement system was developed
using open-source platforms. The system was based on the RZB-04-04 dosimetry gate …

[PDF][PDF] Measurement of dead time of detector using the attenuation law-based method.

M Tabish, U Gupta, A Yadav, S Bhattacharya, A Goel - resources.inmm.org
Radioactive decays are completely random processes, for accurate detection and
quantification of information regarding the source and its strength, we must understand the …