Electrokinetics of non-Newtonian fluids: a review

C Zhao, C Yang - Advances in colloid and interface science, 2013 - Elsevier
This work presents a comprehensive review of electrokinetics pertaining to non-Newtonian
fluids. The topic covers a broad range of non-Newtonian effects in electrokinetics, including …

[图书][B] Engineering haptic devices

TA Kern, C Hatzfeld, A Abbasimoshaei - 2023 - library.oapen.org
This is an open access book. In this third edition of Engineering Haptic Devices the software
part was rewritten from scratch and now includes even more details on tactile and texture …

Active knee rehabilitation orthotic device with variable damping characteristics implemented via an electrorheological fluid

J Nikitczuk, B Weinberg, PK Canavan… - … ASME transactions on …, 2009 - ieeexplore.ieee.org
This paper presents a novel, smart, and portable active knee rehabilitation orthotic device
(AKROD) that provides variable damping at the knee joint, controlled in ways that can …

Design, control and human testing of an active knee rehabilitation orthotic device

B Weinberg, J Nikitczuk, S Patel… - … on Robotics and …, 2007 - ieeexplore.ieee.org
This paper presents a novel, smart and portable active knee rehabilitation orthotic device
(AKROD) designed to train stroke patients to correct knee hyperextension during stance and …

Transient heat transfer and electro-osmotic flow of Carreau–Yasuda non-Newtonian fluid through a rectangular microchannel

S Ghorbani, A Emamian, A Amiri Delouei… - International Journal of …, 2023 - emerald.com
Purpose The purpose of this study is to investigate heat transfer and electrokinetic non-
Newtonian flow in a rectangular microchannel in the developed and transient states …

[图书][B] Entwicklung Haptischer Geräte: Ein Einstieg für Ingenieure

TA Kern - 2009 - Springer
Die folgenden Tabellen stellen eine Sammlung aller den Autoren geläufigen Namen und
Gruppen dar. Die Listen sind naturgemäß nicht vollständig, geben aber einen Einstieg in die …

MR_CHIROD v. 2: magnetic resonance compatible smart hand rehabilitation device for brain imaging

A Khanicheh, D Mintzopoulos… - … on Neural Systems …, 2008 - ieeexplore.ieee.org
This paper presents the design, fabrication, and testing of a novel, one degree-of-freedom,
magnetic resonance compatible smart hand interfaced rehabilitation device (MR_CHIROD …

fMRI-compatible rehabilitation hand device

A Khanicheh, A Muto, C Triantafyllou… - … of neuroengineering and …, 2006 - Springer
Background Functional magnetic resonance imaging (fMRI) has been widely used in
studying human brain functions and neurorehabilitation. In order to develop complex and …

Characterization and testing of an electrorheological fluid valve for control of ERF actuators

QA Nguyen, SJ Jorgensen, J Ho, L Sentis - Actuators, 2015 - mdpi.com
Previous studies of electrorheological fluids (ERFs) were motivated by brake, clutch,
damping, haptic and resistive applications, but never motivated towards developing an ERF …

Semi-active compliant robot enabling collision safety for human robot interaction

MR Ahmed, I Kalaykov - 2010 IEEE International Conference …, 2010 - ieeexplore.ieee.org
Human robot interaction (HRI) tasks requires robots to have safe sharing of work space and
to demonstrate adaptable compliant behavior enabling eminent collision safety as well as …