RADIANCE—A planning software for intra-operative radiation therapy

MF Valdivieso-Casique, R Rodríguez… - Translational cancer …, 2015 - tcr.amegroups.org
In the last decades accumulated clinical evidence has proven that intra-operative radiation
therapy (IORT) is a very valuable technique. In spite of that, planning technology has not …

XIORT‐MC: A real‐time MC‐based dose computation tool for low‐energy X‐rays intraoperative radiation therapy

P Ibáñez, A Villa‐Abaunza, M Vidal, P Guerra… - Medical …, 2021 - Wiley Online Library
Purpose The INTRABEAM system is a miniature accelerator for low‐energy X‐ray Intra‐
Operative Radiation Therapy (IORT), and it could benefit from a fast and accurate dose …

Automatic phase space generation for Monte Carlo calculations of intensity modulated particle therapy

Q Wang, C Zhu, X Bai, Y Deng… - Biomedical Physics …, 2020 - iopscience.iop.org
Monte Carlo (MC) is generally considered as the most accurate dose calculation tool for
particle therapy. However, a proper description of the beam particle kinematics is a …

Fast optimized Monte Carlo phase-space generation and dose prediction for low energy x-ray intra-operative radiation therapy

M Vidal, P Ibáñez, P Guerra… - Physics in Medicine …, 2019 - iopscience.iop.org
Low energy x-ray intra-operative radiation therapy (IORT) is used mostly for breast cancer
treatment with spherical applicators. X-ray IORT treatment delivered during surgery (ex …

[HTML][HTML] Evaluation of RADIANCE Monte Carlo algorithm for treatment planning in electron based Intraoperative Radiotherapy (IOERT)

C Iliaskou, G Rossi, I Sachpazidis, V Boronikolas… - … für Medizinische Physik, 2024 - Elsevier
Purpose To perform experimental as well as independent Monte Carlo (MC) evaluation of
the MC algorithm implemented in RADIANCE version 4.0. 8, a dedicated treatment planning …

Intraoperative computed tomography imaging for dose calculation in intraoperative electron radiation therapy: Initial clinical observations

V García-Vázquez, FA Calvo, MJ Ledesma-Carbayo… - PLoS …, 2020 - journals.plos.org
In intraoperative electron radiation therapy (IOERT) the energy of the electron beam is
selected under the conventional assumption of water-equivalent tissues at the applicator …

Dosimetric study of bevel factors in IOERT with mobile linacs: Towards a unified code of practice

R Ayala, R García, G Ruiz, MJ García, Á Soza… - Physica Medica, 2024 - Elsevier
Background: Dosimetry in intraoperative electron radiotherapy (IOERT) poses distinct
challenges, especially with inclined applicators deviating from international protocols. Ion …

Surface scanning for 3D dose calculation in intraoperative electron radiation therapy

V García-Vázquez, B Sesé-Lucio, FA Calvo… - Radiation …, 2018 - Springer
Background Dose calculations in intraoperative electron radiation therapy (IOERT) rely on
the conventional assumption of water-equivalent tissues at the applicator end, which defines …

Advanced design of radiotherapy equipment: IORT and small animal irradiators

A Villa Abaunza - 2022 - docta.ucm.es
Cancer is a major public health problem worldwide and the leading cause of death in Spain
[1]. Radiotherapy plays an important role in cancer treatment with approximately 50% of all …

A Monte Carlo‐based dosimetric characterization of Esteya®, an electronic surface brachytherapy unit

C Valdes‐Cortez, Y Niatsetski… - Medical …, 2019 - Wiley Online Library
Purpose The purpose of this work is threefold: First, to obtain the phase space of an
electronic brachytherapy (eBT) system designed for surface skin treatments. Second, to …