Off-label uses of the Pipeline embolization device: a review of the literature

PD Patel, N Chalouhi, E Atallah, S Tjoumakaris… - Neurosurgical …, 2017 - thejns.org
The Pipeline embolization device (PED) is the most widely used flow diverter in
endovascular neurosurgery. In 2011, the device received FDA approval for the treatment of …

Flow-diverter devices in the treatment of intracranial aneurysms: a meta-analysis and systematic review

X Lv, H Yang, P Liu, Y Li - The Neuroradiology Journal, 2016 - journals.sagepub.com
Objective The purpose of this report was to discuss the overall limitations, safety and efficacy
of flow-diverter stenting for intracranial aneurysms. Methods The authors performed a meta …

Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results

RA Hanel, DF Kallmes, DK Lopes, PK Nelson… - Journal of …, 2020 - jnis.bmj.com
Background Preliminary clinical studies on the safety and efficacy of the pipeline
embolization device (PED) for the treatment of small/medium aneurysms have demonstrated …

Pipeline for uncoilable or failed aneurysms: 3-year follow-up results

T Becske, MB Potts, M Shapiro, DF Kallmes… - Journal of …, 2016 - thejns.org
OBJECTIVE The long-term effectiveness of endovascular treatment of large and giant wide-
neck aneurysms using traditional endovascular techniques has been disappointing, with …

Prospective study on embolization of intracranial aneurysms with the pipeline device (PREMIER study): 3-year results with the application of a flow diverter specific …

RA Hanel, GM Cortez, DK Lopes, PK Nelson… - Journal of …, 2023 - jnis.bmj.com
Background The pipeline embolization device (PED; Medtronic) has presented as a safe
and efficacious treatment for small-and medium-sized intracranial aneurysms …

Predictors of cerebral aneurysm persistence and occlusion after flow diversion: a single-institution series of 445 cases with angiographic follow-up

MT Bender, GP Colby, LM Lin, B Jiang… - Journal of …, 2018 - thejns.org
OBJECTIVE Flow diversion requires neointimal stent overgrowth to deliver aneurysm
occlusion. The existing literature on aneurysm occlusion is limited by heterogeneous follow …

Safety and efficacy of the Pipeline Embolization Device in 100 small intracranial aneurysms

N Chalouhi, M Zanaty, A Whiting, S Yang… - Journal of …, 2015 - thejns.org
OBJECT Flow diverters are increasingly used for treatment of intracranial aneurysms. In
most series, the Pipeline Embolization Device (PED) was used for the treatment of large …

Expanding indications for flow diverters: distal aneurysms, bifurcation aneurysms, small aneurysms, previously coiled aneurysms and clipped aneurysms, and carotid …

N Limbucci, G Leone, L Renieri, S Nappini… - …, 2020 - journals.lww.com
Flow diverter devices have gained wide acceptance for the treatment of unruptured
intracranial aneurysms. Most studies are based on the treatment of large aneurysms …

Effect of antiplatelet therapy and platelet function testing on hemorrhagic and thrombotic complications in patients with cerebral aneurysms treated with the pipeline …

SL Skukalek, AM Winkler, J Kang, JE Dion… - Journal of …, 2016 - jnis.bmj.com
Purpose The pipeline embolization device (PED) necessitates dual antiplatelet therapy
(APT) to decrease thrombotic complications while possibly increasing bleeding risks. The …

Cerebral aneurysm treatment: modern neurovascular techniques

B Jiang, M Paff, GP Colby, AL Coon… - Stroke and vascular …, 2016 - svn.bmj.com
Cerebral aneurysm treatment: modern neurovascular techniques | Stroke and Vascular
Neurology Skip to main content Viewing from: Google Indexer BMJ Journals Log In More Log in …