[HTML][HTML] Fused deposition modeling PEEK implants for personalized surgical application: from clinical need to biofabrication

L Wang, C Yang, C Sun, X Yan, J He… - … Journal of Bioprinting, 2022 - ncbi.nlm.nih.gov
Abstract Three-dimensional printing (3DP) technology is suitable for manufacturing
personalized orthopedic implants for reconstruction surgery. Compared with traditional …

Development of a full body CAD dataset for computational modeling: a multi-modality approach

FS Gayzik, DP Moreno, CP Geer, SD Wuertzer… - Annals of biomedical …, 2011 - Springer
The objective of this study was to develop full body CAD geometry of a seated 50th
percentile male. Model development was based on medical image data acquired for this …

Effects of sex, age, and two loading rates on the tensile material properties of human rib cortical bone

MJ Katzenberger, DL Albert, AM Agnew… - Journal of the mechanical …, 2020 - Elsevier
The objective of this study was to evaluate the effects of sex, loading rate, and age on the
tensile material properties of human rib cortical bone over a wide range of subject …

Custom design and biomechanical analysis of 3D-printed PEEK rib prostheses

J Kang, L Wang, C Yang, L Wang, C Yi, J He… - … and modeling in …, 2018 - Springer
A tumour resection normally involves a large tissue resection and bone replacement.
Polyether ether ketone (PEEK) has become a suitable candidate for use in various …

Influence of mesh density, cortical thickness and material properties on human rib fracture prediction

Z Li, MW Kindig, D Subit, RW Kent - Medical engineering & physics, 2010 - Elsevier
The purpose of this paper was to investigate the sensitivity of the structural responses and
bone fractures of the ribs to mesh density, cortical thickness, and material properties so as to …

Development of a computationally efficient full human body finite element model

D Schwartz, B Guleyupoglu, B Koya… - Traffic injury …, 2015 - Taylor & Francis
Introduction: A simplified and computationally efficient human body finite element model is
presented. The model complements the Global Human Body Models Consortium (GHBMC) …

Lateral impact validation of a geometrically accurate full body finite element model for blunt injury prediction

NA Vavalle, DP Moreno, AC Rhyne, JD Stitzel… - Annals of biomedical …, 2013 - Springer
This study presents four validation cases of a mid-sized male (M50) full human body finite
element model—two lateral sled tests at 6.7 m/s, one sled test at 8.9 m/s, and a lateral drop …

State of the art in post-mortem forensic imaging in China

Y Chen - Forensic sciences research, 2017 - academic.oup.com
The autopsy and histopathologic examination are traditional and classic approaches in
forensic pathology. In recent years, with the tremendous progresses of computer technology …

Cement augmentation of the proximal femoral nail antirotation for the treatment of two intertrochanteric fractures-a comparative finite element study

L Zheng, X Chen, Y Zheng, X He, J Wu… - BMC Musculoskeletal …, 2021 - Springer
Background There are concerns regarding initial stability and cutout effect in proximal
femoral nail antirotation (PFNA) treating intertrochanteric fractures. No study have used finite …

Three-dimensional printing PEEK implant: a novel choice for the reconstruction of chest wall defect

L Wang, L Huang, X Li, D Zhong, D Li, T Cao… - The Annals of Thoracic …, 2019 - Elsevier
Background The purpose of this study is to use 3-dimensional printing (3DP)
polyetheretherketone (PEEK) implants for skeletal reconstructions after wide excision of …