The bone conduction implant–a review and 1-year follow-up

B Håkansson, S Reinfeldt, AC Persson… - … Journal of Audiology, 2019 - Taylor & Francis
Objective: The objective of this study is to evaluate its safety and effectiveness of the bone
conduction implant (BCI) having an implanted transducer and to review similar bone …

[HTML][HTML] Long-term follow-up and review of the Bone Conduction Implant

S Reinfeldt, M Eeg-Olofsson, KJF Jansson… - Hearing Research, 2022 - Elsevier
Active transcutaneous bone conduction devices are a type of bone conduction device
developed to keep the skin intact and provide direct bone conduction stimulation. The Bone …

MRI after Bonebridge implantation: a comparison of two implant generations

C Utrilla, J Gavilán, P García-Raya, M Calvino… - European Archives of …, 2021 - Springer
Purpose Analysis of head magnetic resonance images (MRI) of patients with active bone
conduction implants (BCIs) is challenging. Currently, there are two generations of the …

[HTML][HTML] Effect of transducer attachment on vibration transmission and transcranial attenuation for direct drive bone conduction stimulation

C Rigato, S Reinfeldt, B Håkansson, KJF Jansson… - Hearing Research, 2019 - Elsevier
Direct drive bone conduction devices (BCDs) are used to rehabilitate patients with
conductive or mixed hearing loss by stimulating the skull bone directly, either with an …

[HTML][HTML] Safety of active auditory implants in magnetic resonance imaging

G Fierens, N Standaert, R Peeters, C Glorieux… - Journal of Otology, 2021 - Elsevier
Magnetic resonance imaging (MRI) has become the gold standard for the diagnosis of many
pathologies. Using MRI in patients with auditory implants can however raise concerns due to …

Postoperative imaging of the internal auditory canal: Visualization of active auditory implants.

I Todt, G Rademacher, P Mittmann, S Mutze, A Ernst - HNO, 2017 - europepmc.org
Background Assessment of the internal auditory canal (IAC) and cochlea is of central
importance in neurotology. The artefacts and visibility of active auditory implants on …

Optimal retention force of audio processor magnets

L Wagner, E Hönig, L Fröhlich, S Plontke… - Otology & …, 2019 - journals.lww.com
Background: The magnetic force required to retain the proper placement of transcutaneous
active hearing implants varies among patients. Currently, audiologists rely on personal …

Metal artefact reduction sequences for a piezoelectric bone conduction implant using a realistic head phantom in MRI

G Fierens, J Walraevens, R Peeters, C Glorieux… - arXiv preprint arXiv …, 2023 - arxiv.org
Industry standards require medical device manufacturers to perform implant-induced artefact
testing in phantoms at a pre-clinical stage to define the extent of artefacts that can be …

Nasal sound pressure as objective verification of implant in active transcutaneous bone conduction devices

S Reinfeldt, C Rigato, B Håkansson… - Medical Devices …, 2019 - Taylor & Francis
Objective: Active transcutaneous bone conduction devices consist of an external audio
processor and an internal implant under intact skin. During the surgical procedure, it is …

Management of conductive hearing loss with implantable bone conduction devices

SN Ghossaini, YLM Ying - … Techniques in Otolaryngology-Head and Neck …, 2024 - Elsevier
Implantable bone conduction devices have been a beneficial addition to the armamentarium
of surgical management of conductive hearing loss. They have demonstrated rapid …