The silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector

S Gundacker, A Heering - Physics in Medicine & Biology, 2020 - iopscience.iop.org
The silicon photomultiplier (SiPM) is an established device of choice for a variety of
applications, eg in time of flight positron emission tomography (TOF-PET), lifetime …

Physics and technology of time-of-flight PET detectors

DR Schaart - Physics in Medicine & Biology, 2021 - iopscience.iop.org
The imaging performance of clinical positron emission tomography (PET) systems has
evolved impressively during the last∼ 15 years. A main driver of these improvements has …

Roadmap toward the 10 ps time-of-flight PET challenge

P Lecoq, C Morel, JO Prior, D Visvikis… - Physics in Medicine …, 2020 - iopscience.iop.org
Since the seventies, positron emission tomography (PET) has become an invaluable
medical molecular imaging modality with an unprecedented sensitivity at the picomolar …

DOI estimation through signal arrival time distribution: a theoretical description including proof of concept measurements

F Loignon-Houle, S Gundacker… - Physics in Medicine …, 2021 - iopscience.iop.org
The challenge to reach 10 ps coincidence time resolution (CTR) in time-of-flight positron
emission tomography (TOF-PET) is triggering major efforts worldwide, but timing …

Front-end design for sipm-based monolithic neutron double scatter imagers

JW Cates, J Steele, J Balajthy, V Negut, P Hausladen… - Sensors, 2022 - mdpi.com
Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to
enable emission imaging of neutron sources. Due to the relatively low coincidence detection …

Toward 100 ps coincidence time resolution using multiple timestamps in depth-encoding PET modules: A Monte Carlo simulation study

A LaBella, S Tavernier, C Woody… - … on Radiation and …, 2020 - ieeexplore.ieee.org
Coincidence time resolution (CTR) in modern time-of-flight (TOF) PET scanners is limited by
properties of the detector system, namely scintillator size and material, as well as single …

Embedded time of arrival estimation for digital silicon photomultipliers with in-pixel TDCs

W Lemaire, F Nolet, F Dubois, AC Therrien… - Nuclear Instruments and …, 2020 - Elsevier
Including precise time-of-flight measurements in the reconstruction of positron emission
tomography (PET) images reduces the required radiotracer dose, scan time and improves …

[PDF][PDF] Électronique d'un convertisseur photon-numérique 3D pour une résolution temporelle de 10 ps FWHM.

F Nolet - 2020 - savoirs.usherbrooke.ca
Les technologies utilisant la détection monophotonique sont de plus en plus présentes dans
nos vies. De nombreuses applications nécessitent un photodétecteur possédant une haute …

Transfer matrix analysis method for lidar modeling in near-infrared region applications

FJK Kareem - 2020 - openaccess.altinbas.edu.tr
With many benefits, single-photon LiDAR (SPL) sensors contend with traditional multi-
photon laser scanning devices. The (SPL) uses a matrix of many single-photon avalanche …

High Resolution Single-ended Readout TOF-DOI PET Using Prismatoid Light Guide Arrays

A LaBella - 2020 - search.proquest.com
Positron emission tomography (PET) is the go-to functional and molecular imaging modality
for a variety of fields, including cardiac imaging and cancer staging. While PET has excellent …