How to measure intraocular pressure: an updated review of various tonometers

P Brusini, ML Salvetat, M Zeppieri - Journal of clinical medicine, 2021 - mdpi.com
Intraocular pressure (IOP) is an important measurement that needs to be taken during
ophthalmic examinations, especially in ocular hypertension subjects, glaucoma patients and …

Identification of biomechanical properties of the cornea: the ocular response analyzer

N Terai, F Raiskup, M Haustein, LE Pillunat… - Current eye …, 2012 - Taylor & Francis
Purpose: Several methods have been devised for measuring geometric parameters of the
cornea but, until now, the biomechanics of the cornea have been largely ignored. The …

Corneal biomechanical properties in different ocular conditions and new measurement techniques

N Garcia-Porta, P Fernandes, A Queiros… - International …, 2014 - Wiley Online Library
Several refractive and therapeutic treatments as well as several ocular or systemic diseases
might induce changes in the mechanical resistance of the cornea. Furthermore, intraocular …

The thick and thin of the central corneal thickness in glaucoma

GW Belovay, I Goldberg - Eye, 2018 - nature.com
Central corneal thickness (CCT) is an important parameter in the assessment of any
potential glaucoma patient. While it affects prognosis in ocular hypertension, its value in …

[HTML][HTML] Comparison of current tonometry techniques in measurement of intraocular pressure

B Kouchaki, H Hashemi, A Yekta - Journal of current ophthalmology, 2017 - Elsevier
Purpose To compare four tonometry techniques: Goldmann applanation tonometer (GAT),
Dynamic contour tonometer (DCT), Non-contact tonometer (NCT), and Ocular Response …

A clinical description of Ocular Response Analyzer measurements

W Lau, D Pye - Investigative ophthalmology & visual science, 2011 - iovs.arvojournals.org
Purpose.: To examine the interrelationships among the Ocular Response Analyzer (ORA;
Reichert Ophthalmic Instruments, Buffalo, NY), Goldmann applanation tonometer (GAT), and …

Early biomechanical keratoconus pattern measured with an ocular response analyzer: curve analysis

D Touboul, A Bénard, AM Mahmoud, A Gallois… - Journal of Cataract & …, 2011 - Elsevier
PURPOSE: To estimate the ability of the Ocular Response Analyzer parameters to aid in the
diagnosis of keratoconus in pre-laser in situ keratomileusis (LASIK) patients. SETTING …

[HTML][HTML] Advances in biomechanical parameters for screening of refractive surgery candidates: a review of the literature, part III

M Moshirfar, MN Motlagh, MS Murri… - … and Innovation in …, 2019 - ncbi.nlm.nih.gov
Corneal biomechanical properties have garnered significant interest in their relation to the
development of ectatic corneal disease. Alongside the advent of corneal tomography and …

Relationship between novel intraocular pressure measurement from Corvis ST and central corneal thickness and corneal hysteresis

M Matsuura, H Murata, Y Fujino… - British Journal of …, 2020 - bjo.bmj.com
Aims Corvis ST (CST) yields biomechanical corrected IOP (bIOP) which is purported to be
less dependent on biomechanical properties. In our accompanied paper, it was suggested …

Corneal biomechanics in different age groups

AAK El Massry, AA Said, IM Osman, AS Bessa… - International …, 2020 - Springer
Purpose To report on the corneal biomechanical characteristics, namely the corneal
hysteresis (CH), corneal resistance factor (CRF), as well as the intraocular pressure (IOP) …