[HTML][HTML] Stereoelectroencephalography versus subdural electrodes for localization of the epileptogenic zone: what is the evidence?

JS Katz, TJ Abel - Neurotherapeutics, 2019 - Elsevier
Accurate and safe localization of epileptic foci is the crux of surgical therapy for focal
epilepsy. As an initial evaluation, patients with drug-resistant epilepsy often undergo …

Stereoelectroencephalography in epilepsy, cognitive neurophysiology, and psychiatric disease: safety, efficacy, and place in therapy

BE Youngerman, FA Khan… - … disease and treatment, 2019 - Taylor & Francis
For patients with drug-resistant epilepsy, surgical intervention may be an effective treatment
option if the epileptogenic zone (EZ) can be well localized. Subdural strip and grid electrode …

The missed value of underutilizing pediatric epilepsy surgery: a systematic review

CW Beatty, JP Lockrow, S Gedela, A Gehred… - Seminars in pediatric …, 2021 - Elsevier
Pediatric epilepsy surgery is underutilized. Only 1%-11% of children with drug resistant
epilepsy (DRE) undergo surgical treatment, or less than half of those estimated to benefit …

Robot-assisted versus manual navigated stereoelectroencephalography in adult medically-refractory epilepsy patients

LH Kim, AY Feng, AL Ho, JJ Parker, KK Kumar… - Epilepsy research, 2020 - Elsevier
Objective Stereoelectroencephalography (SEEG) has experienced a recent growth in
adoption for epileptogenic zone (EZ) localization. Advances in robotics have the potential to …

Comparative effectiveness of stereotactic, subdural, or hybrid intracranial EEG monitoring in epilepsy surgery

R Jha, DD Liu, JVE Gerstl, S Renauld… - Journal of …, 2024 - thejns.org
OBJECTIVE Surgical intervention can be curative or palliative for drug-resistant focal
epilepsy. However, if the seizure onset zone (SOZ) cannot be adequately localized via …

Combining OPM and lesion mapping data for epilepsy surgery planning: a simulation study

S Mellor, RC Timms, GC O'Neill, TM Tierney… - Scientific Reports, 2024 - nature.com
When planning for epilepsy surgery, multiple potential sites for resection may be identified
through anatomical imaging. Magnetoencephalography (MEG) using optically pumped …

Robotically steered needles: A survey of neurosurgical applications and technical innovations

MA Audette, SPA Bordas, JE Blatt - Robotic Surgery: Research …, 2020 - Taylor & Francis
This paper surveys both the clinical applications and main technical innovations related to
steered needles, with an emphasis on neurosurgery. Technical innovations generally center …

Comparison of subdural grid and stereoelectroencephalography in a cohort of pediatric patients

A Talai, K Eschbach, NV Stence, C Palmer, W Bird… - Epilepsy Research, 2021 - Elsevier
Objective To compare adverse events and outcomes between
stereoelectroencephalography (SEEG) and subdural electrode (SDE) implantation in …

Virtual reality–based 3-dimensional localization of stereotactic EEG (SEEG) depth electrodes and related brain anatomy in pediatric epilepsy surgery

TN Phan, KJ Prakash, RJS Elliott, A Pasupuleti… - Child's Nervous …, 2022 - Springer
Introduction The increasing use of stereoelectroencephalography (SEEG) in the USA and
the need for three-dimensional (3D) appreciation of complex spatial relationships between …

Recent advances in the neurosurgical treatment of pediatric epilepsy: JNSPG 75th Anniversary Invited Review Article

JL Roland, MD Smyth - Journal of Neurosurgery: Pediatrics, 2019 - thejns.org
The field of epilepsy surgery has seen tremendous growth in recent years. Innovative new
devices have driven much of this growth, but some has been driven by revisions of existing …