Experimental investigation of the effect of magnetic field on temperature and temperature profile of diffusion flame using circular grating Talbot interferometer

S Agarwal, M Kumar, C Shakher - Optics and Lasers in Engineering, 2015 - Elsevier
The effect of magnetic field on temperature and temperature profile of diffusion flame is
investigated by using circular grating Talbot interferometer. Talbot interferometric fringes are …

Laser differential reflection-confocal focal-length measurement

J Yang, L Qiu, W Zhao, H Wu - Optics Express, 2012 - opg.optica.org
A new laser differential reflection-confocal focal-length measurement (DRCFM) method is
proposed for the high-accuracy measurement of the lens focal length. DRCFM uses weak …

Focal length measurement based on Fresnel diffraction from a phase plate

M Dashtdar, S Mohammad-Ali Hosseini-Saber - Applied optics, 2016 - opg.optica.org
A method based on the Fresnel diffraction of light from the phase step is introduced for
measuring effective focal length (EFL) and back focal length (BFL) of optical imaging …

Laser differential confocal ultra-long focal length measurement

W Zhao, R Sun, L Qiu, D Sha - Optics Express, 2009 - opg.optica.org
A new laser differential confocal focal-length measurement method is proposed for the
measurement of an ultra-long focal-length. The approach proposed uses the property of an …

High-accuracy measurement of the focal length and distortion of optical systems based on interferometry

G Yang, L Miao, X Zhang, C Sun, Y Qiao - Applied optics, 2018 - opg.optica.org
A figure measuring interferometer (FMI) method is proposed for high-accuracy measurement
of the focal length and distortion of optical systems simultaneously. FMI uses the Zernike …

Long focal-length measurement using divergent beam and two gratings of different periods

J Luo, J Bai, J Zhang, C Hou, K Wang, X Hou - Optics Express, 2014 - opg.optica.org
A new accurate method for long focal-length measurement based on Talbot interferometry is
proposed. A divergent beam and two Ronchi gratings of different periods are employed, as …

Technique for the focal-length measurement of positive lenses using Fizeau interferometry

Y Pavan Kumar, S Chatterjee - Applied optics, 2009 - opg.optica.org
We present what we believe is a new technique for the focal-length measurement of positive
lenses using Fizeau interferometery. The technique utilizes the Gaussian lens equation. The …

Calibration method for high-accuracy measurement of long focal length with Talbot interferometry

X Jin, J Zhang, J Bai, C Hou, X Hou - Applied Optics, 2012 - opg.optica.org
In this paper, a new calibration method for accurate long focal-length measurements, based
on Talbot interferometry, is presented. Error analysis is derived in detail by the numerical …

Measurement of focal length using phase shifted moiré deflectometry

S Trivedi, J Dhanotia, S Prakash - Optics and Lasers in Engineering, 2013 - Elsevier
In present communication, a simple technique for determining the focal length using moiré
deflectometry has been proposed. Necessary mathematical premise expressing the focal …

DMD-based single-pixel off-axis holography for lens phase detection

X Tao, A Zhai, W Zhao, D Wang - Optics & Laser Technology, 2024 - Elsevier
The lens phase provides useful information about the optical path length, from which other
key parameters of a lens can be calculated. Yet, the traditional 2D detector-based phase …