Essential considerations for accurate evaluation of photoneutron contamination in Radiotherapy

AH Karimi, H Brkić, D Shahbazi-Gahrouei… - Applied radiation and …, 2019 - Elsevier
Nowadays, high-energy X-rays produced by medical linear accelerators (LINACs) are
widely used in many Radiation Therapy (RT) centers. High-energy photons (> 8 MeV) …

[HTML][HTML] The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam

H Brkić, A Ivković, M Kasabašić, MP Sovilj… - Radiation …, 2016 - Elsevier
At present, high energy electron linear accelerators (LINACs) producing photons with
energies higher than 10 MeV have a wide use in radiotherapy (RT). However, in these …

A passive single-cylindrical neutron spectrometer for photoneutron spectrometry in 10 MV Elekta Precise Linac head

R Tursinah, S Permana, Z Su'ud, A Maulana… - Nuclear Instruments and …, 2024 - Elsevier
Measuring the neutron spectrum on the Linac head using a passive type neutron detector is
relatively easier than an active type detector because it does not require the involvement of …

[PDF][PDF] Accuracy of empirical formulas in evaluation of neutron dose equivalent inside the 60Co vaults reconstructed for medical linear accelerators

A Ivković, D Faj, S Galić, AH Karimi, M Kasabašić… - International Journal of …, 2020 - sid.ir
ABSTRACT Background: In Southeast Europe medical accelerators are sometimes placed
in small vaults originally built for 60Co treatment unit. In order to meet shielding …

Development of a computational pregnant female phantom and calculation of fetal dose during a photon breast radiotherapy

V Kopacin, M Kasabasic, D Faj… - Radiology and …, 2022 - sciendo.com
Background. The incidence of carcinoma during pregnancy is reported to be 1: 1000–1:
1500 pregnancies with the breast carcinoma being the most commonly diagnosed. Since …

[HTML][HTML] Ionizing radiation in electronics from the Compton scattering of quasi-stationary particles generated by characteristic and Bremsstrahlung x rays

SH Min, O Kwon, M Sattorov, S Kim, D Hong, S Kim… - AIP Advances, 2020 - pubs.aip.org
Characteristic x rays generated by a collision between a tungsten target and relativistic
electron beams generated from a compact electrostatic accelerator based on a Marx …

Assessment of human exposure doses received by activation of medical linear accelerator components

DY Lee, JH Kim, ET Park - Journal of Instrumentation, 2017 - iopscience.iop.org
This study analyzes the radiation exposure dose that an operator can receive from
radioactive components during maintenance or repair of a linear accelerator. This study …

The influence of shielding reinforcement in a vault with limited dimensions on the neutron dose equivalent in vicinity of medical electron linear accelerator

A Ivkovic, D Faj, M Kasabasic, MP Sovilj… - Radiology and …, 2020 - sciendo.com
Background High energy electron linear accelerators (LINACs) producing photon beams
with energies higher than 10 MeV are widely used in radiation therapy. In these beams, fast …

Study of Thermal Neutron Flux and Generated Energy from Linac using CR-39 Detector in Liquid Medium

KN Widyanti, CS Widodo, B Bunawas - Natural B, Journal of Health …, 2018 - natural.ub.ac.id
Linac surgery is required in radiotherapy activities. However, if Linac operated more than 8
MV can cause additional radiation of neutrons, as well as triggers forming secondary cancer …

[PDF][PDF] LINEAR ACCELERATORS IN TELERADIOTHERAPY

V Kalinić, D Babić, I Marijanović, D Franjić - Zdravstveni glasnik, 2022 - hrcak.srce.hr
Radiotherapy is a therapeutic method of local treatment of tumors and other types of
diseases using highenergy ionizing radiation. Teleradiotherapy is a type of radiation in …