Frequency split metal artifact reduction (FSMAR) in computed tomography

E Meyer, R Raupach, M Lell, B Schmidt… - Medical …, 2012 - Wiley Online Library
Purpose: The problem of metal artifact reduction (MAR) is almost as old as the clinical use of
computed tomography itself. When metal implants are present in the field of measurement …

[图书][B] Modern diagnostic x-ray sources: technology, manufacturing, reliability

R Behling - 2021 - taylorfrancis.com
Now fully updated, the second edition of Modern Diagnostic X-Ray Sources: Technology,
Manufacturing, Reliability gives an up-to-date summary of X-ray source technology and …

[图书][B] Machine learning for tomographic imaging

G Wang, Y Zhang, X Ye, X Mou - 2019 - iopscience.iop.org
The area of machine learning, especially deep learning, has exploded in recent years,
producing advances in everything from speech recognition and gaming to drug discovery …

Strategies for scatter correction in dual source CT

M Petersilka, K Stierstorfer, H Bruder, T Flohr - Medical physics, 2010 - Wiley Online Library
Purpose: Dual source CT (DSCT) systems utilize two measurement systems (A) and (B)
offset by about 90°. A special challenge in DSCT is cross‐scattered radiation, ie, scattered …

FreeCT_wFBP: a robust, efficient, open‐source implementation of weighted filtered backprojection for helical, fan‐beam CT

J Hoffman, S Young, F Noo, M McNitt‐Gray - Medical physics, 2016 - Wiley Online Library
Purpose: With growing interest in quantitative imaging, radiomics, and CAD using CT
imaging, the need to explore the impacts of acquisition and reconstruction parameters has …

Image reconstruction for the circle-and-arc trajectory

A Katsevich - Physics in Medicine & Biology, 2005 - iopscience.iop.org
Proposed is an exact shift-invariant filtered backprojection algorithm for the circle-and-arc
trajectory. The algorithm has several important features. First, it allows for the circle to be …

Towards an inline reconstruction architecture for micro-CT systems

D Brasse, B Humbert, C Mathelin, MC Rio… - Physics in Medicine …, 2005 - iopscience.iop.org
Recent developments in micro-CT have revolutionized the ability to examine in vivo living
experimental animal models such as mouse with a spatial resolution less than 50 µm. The …

Head motion correction based on filtered backprojection in helical CT scanning

S Jang, S Kim, M Kim, K Son, KY Lee… - IEEE transactions on …, 2019 - ieeexplore.ieee.org
Head motion may unexpectedly occur during a CT scan. It thereby results in motion artifacts
in a reconstructed image and may lead to a false diagnosis or a failure of diagnosis. To …

Direct cone‐beam cardiac reconstruction algorithm with cardiac banding artifact correction

K Taguchi, BS Chiang, IA Hein - Medical physics, 2006 - Wiley Online Library
Multislice helical computed tomography (CT) is a promising noninvasive technique for
coronary artery imaging. Various factors can cause inconsistencies in cardiac CT data …

Method and image reconstruction device for generating computed tomography image data

F Noo, H Schöndube, K Stierstorfer - US Patent 8,050,480, 2011 - Google Patents
Stierstorfer et al. Weighted FBP a simple approximate 3D FBP algorithm for multislice spiral
CT with good dose usage for arbitrary pitch Phys. Med. Bio. vol. 49, pp. 2209-2218, 2004; …