Thermal performance optimization of the underground power cable system by using a modified Jaya algorithm

P Ocłoń, P Cisek, M Rerak, D Taler, RV Rao… - International Journal of …, 2018 - Elsevier
This paper presents a modified Jaya algorithm for optimizing the material costs and electric-
thermal performance of an Underground Power Cable System (UPCS). A High Voltage (HV) …

Numerical simulation of coupled heat, liquid water and water vapor in soils for heat dissipation of underground electrical power cables

E Kroener, A Vallati, M Bittelli - Applied Thermal Engineering, 2014 - Elsevier
The trend towards renewable energy comes along with a more and more decentralized
production of electric energy. As a consequence many countries will have to build hundreds …

The performance analysis of a new thermal backfill material for underground power cable system

P Ocłoń, M Bittelli, P Cisek, E Kroener… - Applied Thermal …, 2016 - Elsevier
Lafarge Gruntar™ material is proposed in this paper as a new thermal backfill component,
and different mass fractions such as 5%, 10%, and 15% are examined. The thermal …

Underground electric cables a correct evaluation of the soil thermal resistance

F Salata, F Nardecchia, A de Lieto Vollaro… - Applied Thermal …, 2015 - Elsevier
Nowadays companies supplying medium/high voltage electric energy, near residential
areas, tend to use underground cables laying. Hence the design engineer is required to …

3-D thermal analysis and contact resistance evaluation of power cable joint

F Yang, P Cheng, H Luo, Y Yang, H Liu… - Applied Thermal …, 2016 - Elsevier
Aiming at the overheating problem of power cable joints, which is mainly caused by great
contact resistance and unqualified installation, a 3-D electromagnetic-thermal model for …

Experimental study of thermal field deriving from an underground electrical power cable buried in non-homogeneous soils

R de Lieto Vollaro, L Fontana, A Vallati - Applied thermal engineering, 2014 - Elsevier
The electrical cables ampacity mainly depends on the cable system operation temperature.
To achieve a better cable utilization and reduce the conservativeness typically employed in …

Experimental validation of a heat transfer model in underground power cable systems

P Ocłoń, J Pobędza, P Walczak, P Cisek, A Vallati - Energies, 2020 - mdpi.com
This paper presents the laboratory test stand that is used for experimental validation of
underground power cable system models. Determination of temperature distribution in the …

An approach to thermal modeling of power cables installed in ducts

G Petrović, M Cvetković, T Garma, T Kilić - Electric power systems research, 2023 - Elsevier
The power cables laying in the urban areas require utilization of the protective ducts, mainly
to facilitate the faulty section replacement. However, the use of cable ducts results in …

Influence of dry ambient conditions on performance of underground medium-voltage DC cables

M Hruška, C Clauser, RW De Doncker - Applied Thermal Engineering, 2019 - Elsevier
In its publication IEC 60287, the International Electrotechnical Commission recommends
procedures for thermal analysis of power cables in the presence of a dry-out zone in the …

Dynamic thermal analysis of underground medium power cables using thermal impedance, time constant distribution and structure function

V Chatziathanasiou, P Chatzipanagiotou… - Applied Thermal …, 2013 - Elsevier
The thermal behavior of a laboratory model for an underground cable has been investigated
experimentally. Temperatures are recorded as a function of time so that the dynamic thermal …