Thermal parameters determination of battery cells by local heat flux measurements

KA Murashko, AV Mityakov, J Pyrhönen… - Journal of Power …, 2014 - Elsevier
A new approach to define of the thermal parameters, such as heat capacity and through-
plane thermal conductivity, of pouch-type cells is introduced. Application of local heat flux …

Determination of the entropy change profile of a cylindrical lithium-ion battery by heat flux measurements

KA Murashko, AV Mityakov, VY Mityakov… - Journal of Power …, 2016 - Elsevier
The popularity of lithium-ion (Li-ion) batteries has increased over the recent years. Because
of the strong dependence of the Li-ion battery operation characteristics on temperature, heat …

Printed circuit board process based thermopile-type heat flux sensor used for monitoring chips

DH Wang, MZ Wang, YH Peng, Y Zhang - Applied Thermal Engineering, 2022 - Elsevier
At present, most of existing heat flux sensors (HFSs) have the disadvantages of large
volume, complex manufacturing process, poor embedding property and affecting existing …

Thermal Performance of Mini Cooling Channels for High-Power Servo Motor with Non-Uniform Heat Dissipation

T Wang, Z Gao, J Bai, Z Wang, K Qiao, P Li - Journal of Thermal Science, 2023 - Springer
High-power servo motor is widely employed as a necessary actuator in flight vehicles. The
urgent problem to be solved restraining the working performance of servo motor is no longer …

An indirect testing method for the mechanical characteristic of multiunit permanent-magnet synchronous machines with concentrated windings

J Zou, D Zeng, Y Xu, B Wang… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
Compared with traditional three-phase machines, multiphase/multiunit permanent-magnet
synchronous machines (PMSM) are more suitable for low-speed high-power applications …

Heat flow dynamics in thermal systems described by diffusive representation

M Dominguez-Pumar, MT Atienza… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
The objective of this paper is to analyze the dynamics of heat flow in thermal structures
working under constant temperature operation. This analysis is made using the tools of …

Influence of Novel Magnetic Screen Structure on Leakage Flux, Losses, and Thermal Field in the End of Turbogenerator

H Jichao, T Mingxuan, M Yue, Q Jiayu… - IEEE Transactions …, 2024 - ieeexplore.ieee.org
The end leakage flux generated by the current in the end winding of the turbogenerator is
large, which has a significant effect on the electromagnetic losses and temperature in the …

Linear temperature distribution sensor using FBG in liquids—Local heat transfer examination application

V Chakravartula, S Rakshit… - IEEE Sensors …, 2021 - ieeexplore.ieee.org
Measuring the rate and direction of heat flow is essential for several scientific applications
and industrial processes. However, the existing heat flux sensors face many drawbacks …

Heat flux control in non-stationary conditions for industry applications

L Dekusha, S Kovtun, O Dekusha - 2019 IEEE 2nd Ukraine …, 2019 - ieeexplore.ieee.org
For industrial control systems, the advantage of directly measuring the heat flux is that, the
controlling the parameters of an object at a temperature, only the consequences of thermal …

[PDF][PDF] Condition monitoring of wind power converters using heat flux sensor

E Baygildina, L Smirnova, R Juntunen… - Int. Rev. Electr …, 2016 - researchgate.net
The application of the gradient heat flux sensor as a failure and aging indicator of the power