[HTML][HTML] The smooth variable structure filter: A comprehensive review

M Avzayesh, M Abdel-Hafez, M AlShabi… - Digital Signal …, 2021 - Elsevier
The smooth variable structure filter (SVSF) is a type of sliding mode filter formulated in a
predictor-corrector format and has seen significant development over the last 15 years. In …

[图书][B] Transformer ageing: monitoring and estimation techniques

TK Saha, P Purkait - 2017 - books.google.com
A one-stop guide to transformer ageing, presenting industrially relevant state-of-the-art
diagnostic techniques backed by extensive research data Offers a comprehensive coverage …

A correction-iteration method for partial discharge localization in transformer based on acoustic measurement

L Zhou, J Cai, J Hu, G Lang, L Guo… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
Velocity of the acoustic signal generated by partial discharge (PD) in the transformer is
considerably affected by temperature. Because of thermosiphon effect, the internal …

[HTML][HTML] Statistics based method for partial discharge identification in oil paper insulation systems

M Kunicki, A Cichoń, Ł Nagi - Electric Power Systems Research, 2018 - Elsevier
An original partial discharge generated in oil insulation identification methodology based on
simultaneously conducted measurements using electrical method, ultra high frequency …

Optimum acoustic sensor placement for partial discharge allocation in transformers

A Hekmati, R Hekmati - IET Science, Measurement & …, 2017 - Wiley Online Library
Partial discharges (PDs) are a cause of degradation of insulation system and its permanent
activity monitoring is used as a tool for insulation condition assessment in power …

Energy conservation‐based thresholding for effective wavelet denoising of partial discharge signals

R Hussein, KB Shaban… - IET Science, Measurement …, 2016 - Wiley Online Library
Recent studies have shown that wavelet transform can effectively be used for noise
reduction in the context of partial discharge (PD) signal detection and classification. Several …

Toward high-accuracy estimation of partial discharge location

WMF Al-Masri, MF Abdel-Hafez… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
In this paper, high-accuracy estimation of partial discharge (PD) location in an oil insulation
system is addressed. The study aims at forming a fault-tolerant PD localization system …

Denoising different types of acoustic partial discharge signals using power spectral subtraction

R Hussein, KB Shaban, AH El‐Hag - High voltage, 2018 - Wiley Online Library
Measuring acoustic emission (AE) of partial discharge (PD) phenomena can be adopted to
estimate the condition of power transformers. However, the environmental noise …

High‐accuracy localisation method for PD in transformers

J Cai, L Zhou, J Hu, C Zhang, W Liao… - IET Science …, 2020 - Wiley Online Library
This study proposes a high‐accuracy method of localising partial discharge (PD) for
transformer fault diagnosis. This study aims to solve the problem of high‐accuracy …

[HTML][HTML] Study on localization of transformer partial discharge source with planar arrangement UHF sensors based on singular value elimination

G Zhang, X Zhang, J Tang, H Cheng - AIP Advances, 2018 - pubs.aip.org
The large-scale power transformer gap leakage electromagnetic wave partial discharge
detection method belongs to the external UHF detection method. This method can perform …