Simulation studies of refrigeration cycles: A review

S Anand, A Gupta, SK Tyagi - Renewable and Sustainable Energy …, 2013 - Elsevier
Presently out of the total energy consumption, a large share of energy is being used by
refrigeration and air conditioning equipments. The present study is based on literature …

Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A

A Arora, SC Kaushik - International journal of refrigeration, 2008 - Elsevier
This paper presents a detailed exergy analysis of an actual vapour compression
refrigeration (VCR) cycle. A computational model has been developed for computing …

Exergy analysis of R413A as replacement of R12 in a domestic refrigeration system

M Padilla, R Revellin, J Bonjour - Energy Conversion and Management, 2010 - Elsevier
This paper deals with an exergy analysis of the impact of direct replacement (retrofit) of R12
with the zeotropic mixture R413A on the performance of a domestic vapour-compression …

Experimental study of new refrigerant mixtures to replace R12 in domestic refrigerators

B Tashtoush, M Tahat, MA Shudeifat - Applied Thermal Engineering, 2002 - Elsevier
An experimental study on the replacement of R12 in domestic refrigerators by new
hydrocarbon/hydrofluorocarbon refrigerant mixtures has been carried out. Parameters and …

Improved energy efficiency for CFC domestic refrigerators retrofitted with ozone-friendly HFC134a/HC refrigerant mixture

SJ Sekhar, DM Lal, S Renganarayanan - International journal of thermal …, 2004 - Elsevier
Conversion of CFC12 systems to eco-friendly ones will be a major thrust area for
refrigeration sector in the near future. As and when an existing CFC (chlorofluorocarbon) …

HFC134a/HC600a/HC290 mixture a retrofit for CFC12 systems

SJ Sekhar, DM Lal - International journal of refrigeration, 2005 - Elsevier
The environmental concerns with the impact of refrigerant emissions lead to the importance
in identifying a long-term alternative to meet all requirements in respect of system …

Experimental study on HFC-161 mixture as an alternative refrigerant to R502

Y Xuan, G Chen - International Journal of Refrigeration, 2005 - Elsevier
Ternary near-azeotropic mixture of HFC-161 as an alternative refrigerant to R502 is firstly
presented in this paper. The physical characteristics of this new refrigerant are similar to …

Screening of pure fluids as alternative refrigerants

B Saleh, M Wendland - International journal of refrigeration, 2006 - Elsevier
Hydrofluorocarbons are now well established as refrigerants because of their zero ozone
depletion potential. Since they have a high global warming potential, other alternatives as …

Performance comparison of CFCs with their substitutes using artificial neural network

E Arcaklioğlu - International Journal of Energy Research, 2004 - Wiley Online Library
In order to decrease global pollution due to chlorofluorocarbons (CFCs), the usage of HFC‐
and HC‐based refrigerants and their mixtures are considered instead of CFCs (R12, R22 …

Thermodynamic analyses of refrigerant mixtures using artificial neural networks

E Arcaklıoğlu, A Çavuşoğlu, A Erişen - Applied energy, 2004 - Elsevier
The aim of this study is to make a contribution towards the efforts of reducing the use of
CFCs by finding a drop-in replacement for pure refrigerants used in domestic and industrial …