Constrained cups appear incapable of meeting the demands of revision THA

PC Noble, SK Durrani, MM Usrey… - Clinical Orthopaedics …, 2012 - journals.lww.com
Background Failure rates of constrained cups for treating recurrent dislocation in revision
THA range from 40% to 100%. Although constrained liners are intended to stabilize the hip …

Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty

J Gallo, V Havranek, J Zapletalova - International orthopaedics, 2010 - Springer
We analysed data from 155 revisions of identical cementless hip prostheses to determine
the influence of patient-, implant-and surgery-related factors on the polyethylene wear rate …

A comparative study of wear laws for soft-on-hard hip implants using a mathematical wear model

L Mattei, F Di Puccio, E Ciulli - Tribology international, 2013 - Elsevier
Wear of UHMWPE acetabular components is the most serious threat to the long-term
success of hip replacements. Consequently numerical and experimental wear simulations …

Volumetric wear assessment of retrieved metal-on-metal hip prostheses and the impact of measurement uncertainty

PJ Bills, R Racasan, RJ Underwood, P Cann, J Skinner… - Wear, 2012 - Elsevier
In hip replacement the use of hard bearing materials, which have been shown to have lower
wear rates than traditional metal-UHMWPE couples, has been encouraged in an effort to …

How to measure wear following total hip arthroplasty

L Grillini, S Affatato - Hip International, 2013 - journals.sagepub.com
Total hip arthroplasty has yielded excellent results in decreasing pain and enhancing
function in patients with hip degenerative disease. However, the problems associated with …

Cup positioning and its effect on polyethylene wear of vitamin E-and non-vitamin E-supplemented liners in total hip arthroplasty: radiographic outcome at 5-year follow …

J Baghdadi, S Alkhateeb, A Roth… - Archives of Orthopaedic …, 2023 - Springer
Background Aseptic loosening remains a challenging problem after total hip arthroplasty.
Accurate cup placement and supplementation of antioxidants in acetabular liners might …

Wear analysis of explanted conventional metal back polyethylene glenoid liners

G Kocsis, CJ Payne, A Wallace, D McNally - Medical Engineering & Physics, 2018 - Elsevier
Introduction Glenoid component wear and loosening is the Achilles heel of total shoulder
replacement. Analysis of failed, revised implants might give an insight into the causes of …

[HTML][HTML] Highly cross-linked versus conventional polyethylene inserts in total hip arthroplasty, a five-year Roentgen stereophotogrammetric analysis randomised …

J van Loon, D Hoornenborg, I Sierevelt… - World journal of …, 2020 - ncbi.nlm.nih.gov
BACKGROUND Polyethylene (PE) particles produced by wear of the acetabular insert are
thought to cause osteolysis and thereby aseptic loosening of the implant in total hip …

Wear pattern observations from TDR retrievals using autoregistration of voxel data

YP Shkolnikov, A Bowden… - Journal of Biomedical …, 2010 - Wiley Online Library
Because of their unique geometry, characterization of wear damage in total disc
replacement (TDR) is difficult. In the article, we developed and validated an automated …

Reliability of a PowerPoint method for wear measurement after total hip arthroplasty: a retrieval study using 3-dimensional laser scanning

HH Yun, WY Shon, JR Yoon, JH Yang… - The Journal of Arthroplasty, 2012 - Elsevier
The purpose of this study was to evaluate the reliability of the PowerPoint (PP)(2007
Version; Microsoft, Redmond, Wash) method for measuring polyethylene liner wear after …