Hearing through bone conduction headsets

S Surendran, S Prodanovic, S Stenfelt - Trends in Hearing, 2023 - journals.sagepub.com
Bone conduction (BC) stimulation has mainly been used for clinical hearing assessment and
hearing aids where stimulation is applied at the mastoid behind the ear. Recently, BC has …

The bone conduction implant–a review and 1-year follow-up

B Håkansson, S Reinfeldt, AC Persson… - … Journal of Audiology, 2019 - Taylor & Francis
Objective: The objective of this study is to evaluate its safety and effectiveness of the bone
conduction implant (BCI) having an implanted transducer and to review similar bone …

[HTML][HTML] The outer ear pathway during hearing by bone conduction

S Surendran, S Stenfelt - Hearing research, 2022 - Elsevier
There have been conflicting reports in the literature about the importance of the induced ear
canal sound pressure for the perception of bone-conducted (BC) sound. Here we …

Analysis of cross-talk cancellation of bilateral bone conduction stimulation

J Wang, Y Chen, S Stenfelt, J Sang, X Li, C Zheng - Hearing Research, 2023 - Elsevier
When presenting a stereo sound through bilateral stimulation by two bone conduction
transducers (BTs), part of the sound at the left side leaks to the right side, and vice versa …

Touch and hearing mediate osseoperception

F Clemente, B Håkansson, C Cipriani, J Wessberg… - Scientific Reports, 2017 - nature.com
Osseoperception is the sensation arising from the mechanical stimulation of a bone-
anchored prosthesis. Here we show that not only touch, but also hearing is involved in this …

The mechanical impedance of the human skull via direct bone conduction implants

B Håkansson, F Woelflin, A Tjellström… - … Devices: Evidence and …, 2020 - Taylor & Francis
Purpose The mechanical skull impedance is used in the design of direct bone drive hearing
systems. This impedance is also important for the design of skull simulators used in …

Characterization and clinical use of bone conduction transducers at extended high frequencies

AK Remenschneider, JT Cheng, BS Herrmann… - Hearing research, 2023 - Elsevier
Measurement of bone conduction (BC) hearing thresholds at extended high frequencies
(EHF; above 8 kHz) is of clinical interest but is technically complicated by limitations in …

Bone conducted vibration is an effective stimulus for otolith testing in cochlear implant patients

L Fröhlich, M Wilke, SK Plontke… - Journal of Vestibular …, 2022 - content.iospress.com
BACKGROUND: Treatment with a cochlear implant (CI) poses the risk of inducing a
behaviorally unmeasurable air-bone gap leading to false negative absence of cervical and …

VEMP using a new low-frequency bone conduction transducer

B Håkansson, KJF Jansson, T Tengstrand… - Medical Devices …, 2018 - Taylor & Francis
Objective A new prototype bone conduction (BC) transducer B250, with an emphasized low-
frequency response, is evaluated in vestibular evoked myogenic potential (VEMP) …

Maximum output and low-frequency limitations of B71 and B81 clinical bone vibrators: implications for vestibular evoked potentials

CG Clinard, EG Piker, AP Thorne, EN Surface… - Ear and …, 2020 - journals.lww.com
Objectives: Bone-conducted vestibular evoked myogenic potentials (VEMPs) are tuned to
have their maximum amplitude in response to tone bursts at or below 250 Hz. The low …