Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left …

JR Gohean, MJ George, TD Pate, M Kurusz… - ASAIO …, 2013 - journals.lww.com
The purpose of this investigation is to use a computational model to compare a
synchronized valveless pulsatile left ventricular assist device with continuous flow left …

Evaluating the hemodynamical response of a cardiovascular system under support of a continuous flow left ventricular assist device via numerical modeling and …

S Bozkurt, KK Safak - Computational and Mathematical …, 2013 - Wiley Online Library
Dilated cardiomyopathy is the most common type of the heart failure which can be
characterized by impaired ventricular contractility. Mechanical circulatory support devices …

Improving Arterial Pulsatility by Feedback Control of a Continuous Flow Left Ventricular Assist Device via in Silico Modeling

S Bozkurt, FN van de Vosse… - … International Journal of …, 2014 - journals.sagepub.com
Purpose Continuous flow left ventricular assist devices (CF-LVADs) generally operate at a
constant speed, which causes a decrease in pulse pressure and pulsatility in the arteries …

Influence of dilated cardiomyopathy and a left ventricular assist device on vortex dynamics in the left ventricle

S Loerakker, LGE Cox, GJF Van Heijst… - Computer Methods in …, 2008 - Taylor & Francis
Together with new developments in mechanical cardiac support, the analysis of vortex
dynamics in the left ventricle has become an increasingly important topic in literature. The …

Preservation of native aortic valve flow and full hemodynamic support with the TORVAD using a computational model of the cardiovascular system

JR Gohean, MJ George, KW Chang, ER Larson… - ASAIO …, 2015 - journals.lww.com
This article describes the stroke volume selection and operational design for the toroidal
ventricular assist device (TORVAD), a synchronous, positive-displacement ventricular assist …

In vivo and simulation study of artificial ventilation effects on energetic variables in cardiosurgical patients

C De Lazzari, M Darowski, P Wolski… - … of Information in …, 2005 - thieme-connect.com
Objectives: The analysis of energetic ventricular variable changes during artificial
ventilation, obtained by numerical simulation was done. Twenty-one sets of hemodynamic …

Theoretical development with proper approximation and the corresponding clinical experiments for PPG sensor monitoring blood flow volume of hemodialysis patients …

PCP Chao, PY Chiang - 2017 International Conference on …, 2017 - ieeexplore.ieee.org
This study proposes a theoretical basis of blood flow volume sensor for arteriovenous fistula
(AVF) of hemodialysis patients in a noninvasive way by means of reflectance-type …

Study of systolic pressure variation (SPV) in presence of mechanical ventilation

F Clemente, C De Lazzari, M Darowski… - … Journal of Artificial …, 2002 - journals.sagepub.com
Systolic pressure variation (SPV) and its components (dUp and dDown) have been
demonstrated to be of interest in assessing preload in mechanically ventilated patients. The …

[HTML][HTML] Cardiac Energetics in Presence of Lung Assist Devices: In Silico Study

C De Lazzari, B Quatember - Modeling and Numerical Simulation of …, 2016 - scirp.org
The treatment with a mechanical ventilator is required whenever a patient's respiratory
system becomes unable to keep the concentrations of O2 and CO2 in blood at tolerable …

Application of a user-friendly comprehensive circulatory model for estimation of hemodynamic and ventricular variables

G Ferrari, M Kozarski, YJ Gu… - … Journal of Artificial …, 2008 - journals.sagepub.com
Purpose Application of a comprehensive, user-friendly, digital computer circulatory model to
estimate hemodynamic and ventricular variables. Methods The closed-loop lumped …