A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications

D Sarrut, M Bardiès, N Boussion, N Freud… - Medical …, 2014 - Wiley Online Library
In this paper, the authors' review the applicability of the open‐source GATE Monte Carlo
simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry …

Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

A PENELOPE‐based system for the automated Monte Carlo simulation of clinacs and voxelized geometries—application to far‐from‐axis fields

J Sempau, A Badal, L Brualla - Medical physics, 2011 - Wiley Online Library
Purpose: Two new codes, penEasy and penEasyLinac, which automate the Monte Carlo
simulation of Varian Clinacs of the 600, 1800, 2100, and 2300 series, together with their …

Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams

ON Vassiliev, TA Wareing, J McGhee… - Physics in Medicine …, 2010 - iopscience.iop.org
A new grid-based Boltzmann equation solver, Acuros™, was developed specifically for
performing accurate and rapid radiotherapy dose calculations. In this study we …

Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157

CMC Ma, IJ Chetty, J Deng, B Faddegon… - Medical …, 2020 - Wiley Online Library
Dose calculation plays an important role in the accuracy of radiotherapy treatment planning
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …

Dose specification for radiation therapy: dose to water or dose to medium?

CM Ma, J Li - Physics in Medicine & Biology, 2011 - iopscience.iop.org
Abstract The Monte Carlo method enables accurate dose calculation for radiation therapy
treatment planning and has been implemented in some commercial treatment planning …

The international commission on radiation units and measurements

HG Menzel - Journal of the ICRU, 2012 - journals.sagepub.com
The International Commission on Radiation Units and Measurements - Hans-Georg Menzel,
2012 Skip to main content Scheduled maintenance on Monday, November 20th, with …

PRIMO: a graphical environment for the Monte Carlo simulation of Varian and Elekta linacs

M Rodriguez, J Sempau… - Strahlentherapie und …, 2013 - search.proquest.com
Abstract The accurate Monte Carlo simulation of a linac requires a detailed description of its
geometry and the application of elaborate variance-reduction techniques for radiation …

Anatomical imaging for radiotherapy

PM Evans - Physics in Medicine & Biology, 2008 - iopscience.iop.org
The goal of radiation therapy is to achieve maximal therapeutic benefit expressed in terms of
a high probability of local control of disease with minimal side effects. Physically this often …

[PDF][PDF] Dose calculation algorithms in external beam photon radiation therapy

L Lu - International Journal of Cancer Therapy and Oncology, 2014 - core.ac.uk
Model-based algorithm starts first from physics princip and then simplifying the procedure
describing the act physical transport to expedite the calculation. These physi processes …