A survey of diagnostic and condition monitoring of metal oxide surge arrester in the power distribution network

B Ranjbar, A Darvishi, R Dashti, HR Shaker - Energies, 2022 - mdpi.com
Metal oxide surge arresters (MOSAs) are a popular solution for dealing with overvoltages
due to lightning and switching in power distribution networks. As a result, a MOSA's …

Recent development in condition monitoring methodologies of MOSA employing leakage current signal: A review

AK Das, S Dalai - IEEE Sensors Journal, 2021 - ieeexplore.ieee.org
With the rapid development of electric power grid, the application of Metal Oxide Surge
Arrester (MOSA) in electrical power system network has been enhanced. MOSA has been …

Harmonic analysis of metal oxide surge arrester leakage current considering fan-shaped type pollution effect

MH Teymourian, S Seyyedbarzegar… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
This article investigates the leakage current (LC) analysis of metal oxide surge arresters
(MOSAs) under both uniform and fan shape as a nonuniform pollution conditions and at …

Parameter extraction for the degradation of on-board arrester in high-speed railway under effects of multiple strokes

L Zhou, L Huang, Z Lin, R Wei, D Wang… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
On-board arrester (OBA) is an essential equipment of electric multiple units (EMUs), and its
working condition will directly affect the reliable operation of EMU. Simultaneously, due to …

New criteria for metal oxide surge arrester condition monitoring based on leakage current analysis: Considering non‐uniform pollution effect

M Khodsuz, MH Teymourian… - IET Generation …, 2024 - Wiley Online Library
The role of surge arresters is vital in power systems' protection against transient
overvoltages, which can arise due to occurrences like lightning strikes or switching …

Estimation of metal oxide surge arresters' useful life based on time series forecasts

VRN Barbosa, GRS Lira, MBB Dias… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Estimating equipment useful life has been a challenge over the years. In this work, a
methodology based on the application of a combined time series forecast model composed …

Leakage Current Measurements of Surge Arresters

M Olesz, LS Litzbarski, G Redlarski - Energies, 2023 - mdpi.com
The paper presents the methods of assessing the technical condition of varistor surge
arresters used in laboratory tests and in operation—performed without disconnecting the …

Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester

AH Khavari, A Munir, Z Abdul-Malek - Bulletin of Electrical Engineering and …, 2020 - beei.org
Resistive leakage current based condition assessment of metal oxide surge arrester (MOSA)
is one of the most extensively employed technique to monitor its degradation. An extraction …

Thermal behaviour analysis in a porcelain‐housed ZnO surge arrester by computer simulations and thermography

AF Andrade, EG Costa, JMB Fernandes… - High …, 2019 - Wiley Online Library
In this article, an analysis of heat transfer in a porcelain‐housed ZnO surge arrester is
presented. Due to the fact that ZnO‐based surge arresters are key components for protection …

Analysis of Determining the Surge Arrester Protective Distance for Protection on 60 MVA Power Transformers at the 150 KV Main Substation in Surabaya Barat

RS Widagdo, G Budiono… - Jurnal Riset Rekayasa …, 2024 - jurnalnasional.ump.ac.id
Because it provides electrical energy to customers that require protection from lightning
interference, the substation is a crucial location. An electrical equipment's defense against …