Building damages during the September 19, 2017 earthquake in Mexico City and seismic retrofitting of existing first soft-story buildings

JM Jara, EJ Hernández, BA Olmos, G Martínez - Engineering Structures, 2020 - Elsevier
Abstract A strong earthquake (Mw= 7.1) hit Mexico City at 13: 14 local time on September
19, 2017. The earthquake severely damaged more than 600 buildings and more than 1000 …

Assessment of seismic design parameters of moment resisting RC braced frames with metallic fuses

A Tena-Colunga, HJ Nangullasmú-Hernández - Engineering Structures, 2015 - Elsevier
A parametric study was devoted to evaluate, using static nonlinear analyses (pushover),
global seismic design parameters for low to medium rise regular reinforced concrete …

Effect of epicentral distance on the applicability of base isolation and energy dissipation systems to improve seismic behavior of RC buildings

JM Jara, EJ Hernández, BA Olmos - Engineering Structures, 2021 - Elsevier
Even though the intense seismic activity in Mexico and the great human and material losses
produced in the country during the September 19th, 1985 and 2017 earthquakes, the use of …

[HTML][HTML] Requisitos mínimos de detallado dúctil en marcos de concreto reforzado protegidos con disipadores histeréticos de energía

HJ Nangullasmú Hernández, A Tena Colunga - Ingeniería sísmica, 2016 - scielo.org.mx
En este trabajo los autores presentan los resultados de un estudio paramétrico, efectuados
mediante análisis estáticos no lineales (pushover), de marcos de concreto reforzado con …

Seismic response of buildings with energy dissipating systems built in soft soils

JM Jara - Engineering Structures, 2009 - Elsevier
A parametric study of buildings retrofitted with metallic yielding energy dissipation devices
built on soft soil sites is presented. Buildings with 6, 15 and 30 stories are analyzed as …

[HTML][HTML] Inelastic seismic response of building with friction damper

S Banerjee, SK Patro - Journal of The Institution of Engineers (India) …, 2016 - Springer
Dampers are used to control response of structure in recent years. Seismic response is
reduced by adding energy dissipation capacity to the building. Dampers are provided to …

[PDF][PDF] Assessment of global design parameters for ductile steel moment frames with metallic energy dissipators

A Tena-Colunga… - Memorias, 14th World …, 2015 - researchgate.net
In this paper the authors summarize the results of a parametric study devoted to evaluate,
using static nonlinear analyses (pushover), the seismic behavior of low to medium rise …

Evaluation of degrading hysteresis on RC structures retrofitted with energy dissipating systems

JM Jara, BA Olmos, G Martínez - Journal of Building Pathology and …, 2023 - Springer
Passive control devices are currently used in several countries to improve the seismic
response of structures. These novel technologies include energy dissipating systems to …

[HTML][HTML] Strength and stiffness parameters of energy dissipation devices for the seismic protection of building on soft soils

JM Jara, BA Olmos, G Martínez - Bulletin of Earthquake Engineering, 2018 - Springer
Energy dissipation devices are continuously implemented in several buildings and bridges
around the world. The dynamic characteristics of the strong motions in soft soil sites make …

[PDF][PDF] Importance of ductile confinement in reinforced concrete frames with structural fuses

HJ Nangullasmú-Hernández… - 16th World Conference …, 2017 - wcee.nicee.org
In this paper the authors summarize the results obtained, from static nonlinear analyses
(pushover), for reinforced concrete intermediate moment-resisting frames (RC-IMRFs) …