Relation between transmission lines coupling factor and over head earth wire length: its impacts on fault current distributions

M Nassereddine, J Rizk, A Hellany… - IET Generation …, 2014 - Wiley Online Library
High voltage (HV) transmission mains form important assets in electrical networks. The
existence of this infrastructure within the community necessitates effective earthing design to …

Fault current distribution and pole earth potential rise (EPR) under substation fault

M Nnassereddine, J Rizk, A Hellany… - International journal of …, 2013 - degruyter.com
New high-voltage (HV) substations are fed by transmission lines. The position of these lines
necessitates earthing design to ensure safety compliance of the system. Conductive …

[PDF][PDF] AC Interference study on piipeline: ohew split factor impacts on the induced voltage

M Nassereddine, J Rizk, A Hellany… - Journal of Electrical …, 2014 - researchgate.net
Human Safety due to electrical induced voltage is gaining more attention in the area of high
voltage sector. In existing researches, no evidence is cited on the effect that the OHEW split …

Induced voltage behavior on pipelines due to HV AC interference under broken OHEW

M Nassereddine, J Rizk, A Hellany… - 2015 IEEE 10th …, 2015 - ieeexplore.ieee.org
To meet the high demands on the electrical power due to the growth in populations more
high voltage projects are captured by the development scopes. To save on easement cost …

Substation and transmission lines earthing system design under substation fault

M Nassereddine, J Rizk, M Nagrial… - … Power Components and …, 2015 - Taylor & Francis
High-voltage substations are fed by transmission lines with the earthing system solidly
bonded to the substation earth grid. Under substation fault, both the substation earth grid …

OHEW types and its implications on pole EPR under pole fault

M Nassereddine, J Rizk, A Hellany… - 2013 IEEE 8th …, 2013 - ieeexplore.ieee.org
High Voltage (HV) transmission mains form important assets in electrical networks. The
existence of these infrastructures within the community necessitates earthing design to …

HV substation fault and its impacts on HV cable: Safety procedures

M Nassereddine, J Rizk, M Nagrial… - 2016 IEEE International …, 2016 - ieeexplore.ieee.org
The demand on High voltage (HV) infrastructures is growing due to the corresponding
growth in industries and population. To meet the increasing electrical demand, existing …

Wind farm earthing system design using clustering technique

M Nassereddine, J Rizk, M Nagrial… - … Power Components and …, 2015 - Taylor & Francis
A wind farm consists of large number of turbines, the earth grids of which are connected
together. Under fault condition at one turbine, only limited numbers of turbines are impacted …

Earth Potential Rise in Public Spaces Near Telecommunications Facilities

R Narayan, S Harshavandhana - 2018 IEEE International …, 2018 - ieeexplore.ieee.org
The traditional telecommunications networks were housed in buildings and in shelters and
cabinets in well gated areas, often several hundred meters or more away from areas of very …

Wind farm earthing system design under fault at the substation and the turbine

M Nassereddine, J Rizk, M Nagrial… - 2014 Australasian …, 2014 - ieeexplore.ieee.org
Renewable energy projects are developed worldwide. Wind energy form one of the main
part of the renewable energy project. Wind farm consists of numerous number of wind …