Hemolysis during short-term mechanical circulatory support: from pathophysiology to diagnosis and treatment

T Balthazar, J Bennett… - Expert review of medical …, 2022 - Taylor & Francis
Introduction Despite advances in heart failure therapies and percutaneous coronary
interventions, survival for cardiogenic shock remains poor. Percutaneous ventricular assist …

Design of artificial vascular devices: Hemodynamic evaluation of shear-induced thrombogenicity

T Feaugas, G Newman, ST Calzuola… - Frontiers in …, 2023 - frontiersin.org
Blood-circulating devices such as oxygenators have offered life-saving opportunities for
advanced cardiovascular and pulmonary failures. However, such systems are limited in the …

Step by step daily management of short-term mechanical circulatory support for cardiogenic shock in adults in the intensive cardiac care unit: a clinical consensus …

JE Møller, A Sionis, N Aissaoui, A Ariza… - … Heart Journal: Acute …, 2023 - academic.oup.com
The use of mechanical circulatory support using percutaneous ventricular assist devices
(pVAD) has increased rapidly during the last decade without substantial new evidence for …

Shear Force-Induced Platelet Clearance Is a New Mechanism of Thrombocytopenia

A Rauch, A Dupont, M Rosa, M Desvages… - Circulation …, 2023 - Am Heart Assoc
BACKGROUND: Thrombocytopenia has been consistently described in patients with
extracorporeal membrane oxygenation (ECMO) and associated with poor outcome …

Hemodynamic and recirculation performance of dual lumen cannulas for venovenous extracorporeal membrane oxygenation

LP Parker, A Svensson Marcial, TB Brismar… - Scientific Reports, 2023 - nature.com
Venovenous extracorporeal membrane oxygenation (ECMO) can be performed with two
single lumen cannulas (SLCs) or one dual-lumen cannula (DLC) where low recirculation …

[HTML][HTML] Discrete responses of erythrocytes, platelets, and von Willebrand factor to shear

CHH Chan, MJ Simmonds, KH Fraser, K Igarashi… - Journal of …, 2022 - Elsevier
Despite decades of technological advancements in blood-contacting medical devices,
complications related to shear flow-induced blood trauma are still frequently observed in …

Development and validation of a mathematical model for evaluating shear-induced damage of von Willebrand factor

Y Li, Y Xi, H Wang, A Sun, L Wang, X Deng… - Computers in Biology …, 2023 - Elsevier
Purpose To develop a mathematical model for predicting shear-induced von Willebrand
factor (vWF) function modification which can be used to guide ventricular assist devices …

A mathematical model for assessing shear induced bleeding risk

Y Li, H Wang, Y Xi, A Sun, L Wang, X Deng… - Computer Methods and …, 2023 - Elsevier
Purpose The objective of this study is to develop a bleeding risk model for assessing device-
induced bleeding risk in patients supported with blood contact medical devices (BCMDs) …

Role of thrombin to non-physiological shear stress induced platelet activation and function alternation

W Sun, D Han, MA Awad, JL Leibowitz, BP Griffith… - Thrombosis …, 2022 - Elsevier
Objective Non-physiological shear stress (NPSS) and thrombin have two distinct
mechanisms for activating platelets. NPSS in mechanically assisted circulation (MAC) …

Acquired platelet defects are responsible for nonsurgical bleeding in left ventricular assist device recipients

K Arias, W Sun, S Wang, EN Sorensen, E Feller… - Artificial …, 2022 - Wiley Online Library
Background Left ventricular assist devices (LVADs) have been used as a standard treatment
option for patients with advanced heart failure. However, these devices are prone to adverse …