M Kamaya - Nuclear Engineering and Design, 2013 - Elsevier
Cracks detected by in-service inspections are not always removed when they are judged to be not hazardous. In order to secure the integrity of the cracked components, it is important …
Primary loop piping integrity is a regulatory and safety concern for the long-term operation (LTO) commercial light water reactor (LWR) nuclear power plants (NPPs). Typically, primary …
M Kamaya - Progress of Nuclear Safety for Symbiosis and …, 2014 - Springer
Cracks detected during in-service inspections are not always removed when they are judged as hazardous. It is important to monitor the crack growth in order to secure the …
抄録 A monitoring method using strain gages has been proposed by the present authors. This method estimates the crack depth from the change in outside strains due to internal …