State-of-the-art review on the bond properties of corroded reinforcing steel bar

H Lin, Y Zhao, P Feng, H Ye, J Ozbolt, C Jiang… - … and Building Materials, 2019 - Elsevier
This review summarizes the latest research progress in regard to the bond behavior of
corroded reinforcing steel bar. The literature survey indicates that the previous studies …

Carbonation-induced and chloride-induced corrosion in reinforced concrete structures

Y Zhou, B Gencturk, K Willam, A Attar - Journal of Materials in Civil …, 2015 - ascelibrary.org
Corrosion is one of the most critical problems that impair the durability of RC structures. Both
carbonation-induced and chloride-induced corrosion widely prevail in civil infrastructure …

Experimental investigation on rehabilitation of corroded RC columns with BSP and HPFL under combined loadings

H Huang, M Huang, W Zhang, S Pospisil… - Journal of Structural …, 2020 - ascelibrary.org
This research focuses on evaluating the seismic properties of corrosion-damaged RC
columns strengthened by bonded steel plate (BSP) and high-performance ferrocement …

Degradation of steel-to-concrete bond due to corrosion

C Jiang, YF Wu, MJ Dai - Construction and Building Materials, 2018 - Elsevier
Degradation of the bond between steel bars and concrete due to corrosion of steel
significantly affects the durability of reinforced concrete (RC) structures. There are three …

Pitting corrosion and structural reliability of corroding RC structures: Experimental data and probabilistic analysis

MG Stewart, A Al-Harthy - Reliability engineering & system safety, 2008 - Elsevier
A stochastic analysis is developed to assess the temporal and spatial variability of pitting
corrosion on the reliability of corroding reinforced concrete (RC) structures. The structure …

Bond behaviour of normal/recycled concrete and corroded steel bars

Y Zhao, H Lin, K Wu, W Jin - Construction and building materials, 2013 - Elsevier
Pullout and beam tests were performed to study the bond behaviour between normal
aggregate concrete (NAC) or recycled aggregate concrete (RAC) and corroded steel bars …

Effects of confinements on the bond strength between concrete and corroded steel bars

H Lin, Y Zhao - Construction and Building Materials, 2016 - Elsevier
The bond tests were carried out on 18 beam specimens to investigate the bond behavior
between concrete and corroded steel bars, with corrosion and stirrups being the principal …

[PDF][PDF] Long-term performance of corrosion-damaged reinforced concrete beams

T El Maaddawy, K Soudki, T Topper - ACI Structural Journal, 2005 - academia.edu
This paper presents the results of an experimental study designed to investigate the
combined effect of corrosion and sustained loads on the structural performance of reinforced …

A probabilistic bond strength model for corroded reinforced concrete based on weighted averaging of non-fine-tuned machine learning models

B Fu, SZ Chen, XR Liu, DC Feng - Construction and Building Materials, 2022 - Elsevier
This paper develops an innovative probabilistic predictive model for bond strength of
corroded reinforced concrete based on the weighted averaging of non-fine-tuned machine …

The bond behavior between concrete and corroded steel bar under repeated loading

H Lin, Y Zhao, J Ožbolt, R Hans-Wolf - Engineering Structures, 2017 - Elsevier
Repeated loading can affect the serviceability of RC structures by causing the bond
deterioration. In the present study a series of pull-out tests have been carried out to …