[HTML][HTML] Harmonic and supraharmonic emissions of plug-in electric vehicle chargers

A Mariscotti - Smart Cities, 2022 - mdpi.com
Electric vehicle (EV) charging represents a relevant electric load with a rapid evolution in
terms of number, power rating and distortion, in particular, considering the connection to the …

[HTML][HTML] Supraharmonic and harmonic emissions of a bi-directional V2G electric vehicle charging station and their impact to the grid impedance

B Grasel, J Baptista, M Tragner - Energies, 2022 - mdpi.com
Bidirectional electric vehicle supply equipment and charging stations (EVSE) offer new
business models and can provide services to the electrical grid. The smart grid lab in Vienna …

Recent developments in harmonic resonance detection in low voltage networks using impedance measurement techniques

S Kannan, J Meyer - 2019 8th International Conference on …, 2019 - ieeexplore.ieee.org
Harmonic resonance is a modern-age power quality issue. These issues are observed in
public Low Voltage networks caused by increased penetration of diverse power electronic …

Probabilistic stability analysis for commercial low power inverters based on measured grid impedances

E Kaufhold, J Meyer, S Müller… - 2019 9th International …, 2019 - ieeexplore.ieee.org
This paper presents a probabilistic stability analysis of commercial inverters. The set of
chosen inverters consists of common types of rooftop inverters for photovoltaic (PV)-system …

Impact of grid impedance and their resonance on the stability of single-phase PV-inverters in low voltage grids

E Kaufhold, J Meyer, P Schegner - 2020 IEEE 29th …, 2020 - ieeexplore.ieee.org
This paper studies the behavior of grid-connected single-phase photovoltaic inverters in low
voltage grids. The interaction of the inverter control, the grid-side filter and the power grid …

Characteristic leakage current of household devices and their impact on the tripping behaviour of residual current devices

F Möller, AM Blanco, J Meyer - Electric Power Systems Research, 2023 - Elsevier
Power electronic devices can produce distorted leakage currents that might cause
malfunctions in protection devices, which can lead to dangerous situations. This article …

Generic frequency‐domain model for the emission of PWM‐based power converters in the frequency range from 2 to 150 kHz

M Klatt, R Stiegler, J Meyer… - IET Generation …, 2019 - Wiley Online Library
With an increasing number of power converters using fast switching technologies, more
cases of interference between devices in the frequency range from 2 to 150 kHz occur. The …

The role of supply conditions on the measurement of high-frequency emissions

AJ Collin, A Delle Femine, C Landi… - IEEE Transactions …, 2020 - ieeexplore.ieee.org
A standardized measurement procedure and source specification for laboratory high-
frequency (HF, 2-150 kHz) emissions tests of low-voltage (LV) electronic equipment are still …

Measurement and Analysis of the Low Voltage Network Impedance in the Supraharmonic Range

V Erhan, TMH Slangen, V Ćuk… - … on Harmonics & …, 2022 - ieeexplore.ieee.org
The supraharmonic distortion levels and their propagation in low voltage networks are
determined by the supraharmonic-or frequency-dependent network impedance (FDNI) …

[PDF][PDF] Measurements and simulation of supraharmonic resonances in public low voltage networks

M Klatt, F Kaiser, J Meyer, C Lakenbrink, C Gaßner - 2019 - cired-repository.org
Voltages and currents in the frequency range from 2 to 150 kHz (supraharmonics) are
generally assumed to have a short distance of propagation. They are expected to be …