[PDF][PDF] Evaluation of the effects of inhomogeneities on dose profiles using polymer gel dosimeter and Monte Carlo simulation in Gamma Knife

PT ALLAHVERDI, M Allahverdi, MH ZAHMATKESH - 2012 - sid.ir
Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for
conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In …

[PDF][PDF] An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of …

SM Abtahi, RJ Khalilabadi, S Aftabi - International Journal of Radiation …, 2017 - sid.ir
Background: There are various methods to read out responses of a polymer-gel dosimeter,
among which the Magnetic Resonance Imaging (MRI) technique is the most common one …

A new approach to optimize the genipin gel dosimeter formulation

SMM Abtahi, F Bahrami… - International Journal of …, 2024 - search.proquest.com
Background: In this work, we investigated the effect of adding 0.3% w/w of the non-toxic
substance agarose to the dosimeter formulation of genipin radiochromic gel, which was …

Evaluation of dose profiles using Gafchromic EBT3 films in Leksell Gamma Knife 4C around inhomogeneities in the treatment of pituitary adenoma in anthropomorphic …

M Najafi, A Shirazi, G Geraily, M Esfahani… - Radiation Physics and …, 2018 - Elsevier
Abstract Purpose The Leksell Gamma Knife is a complete system for radiosurgery.
Treatment dose planning of Gamma Knife assumes the human head as a homogenous …

Dosimetric evaluation of small IMRT beamlets in the presence of bone inhomogeneity using NIPAM polymer gel and Monte Carlo simulation

S Ghaseminejad, A Mesbahi, A Khajeali… - Radiation …, 2017 - Elsevier
The dose variations in the presence of bone inhomogeneity were investigated for 6 and 18
MV beams, using NIPAM polymer gel in the three field sizes, including 3× 3, 2× 2 and 1× 1 …

[PDF][PDF] Readout temperature effect on the response of the genipin gel dosimeter

F Bahrami, SMM Abtahi, D Sardari… - International Journal of …, 2021 - academia.edu
Background: The present study aimed to investigate the dependence of the response of the
genipin gel dosimeter on readout temperatures. Materials and Methods: To this aim, after the …

[PDF][PDF] HVL evaluation of orthovoltage X-ray machine using EGSnrc code of simulation

MA SHABESTANI, PT ALLAHVERDI, H Babapour… - 2014 - sid.ir
Background: Making use of the ORTHOVOLTAGE MACHINE s in Radiotherapy, is one of the
routine methods for the treatment of the superficial lesions. In this study, an important …

[PDF][PDF] Dose response evaluation of a low density anoxic polymer gel dosimeter using MRI

Background: The human body contains of different tissues and cavities with different
physical and radiological properties. Most important among these are tissues and cavities …

[HTML][HTML] Does nitrogen gas bubbled through a low density polymer gel dosimeter solution affect the polymerization process?

D Shahbazi-Gahrouei, M Gholami… - Advanced biomedical …, 2015 - journals.lww.com
Background: On account of the lower electron density in the lung tissue, the dose distribution
in the lung cannot be verified with the existing polymer gel dosimeters. Thus, the aims of this …

Comparison dose distributions from gamma knife unit 4C with CT data and non-CT data options of beamnrc code

M Bakhshi, G Geraily, A Mostaar… - Iranian Journal of …, 2020 - rsm.kashanu.ac.ir
Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In
order to investigate accuracy of dosimetry and treatment planning calculations, using Monte …