An investigation of the photon energy dependence of the EPR alanine dosimetry system

ES Bergstrand, KR Shortt, CK Ross… - Physics in Medicine & …, 2003 - iopscience.iop.org
The electron paramagnetic resonance (EPR) alanine dosimetry system is based on EPR
measurements of radicals formed in alanine by ionizing radiation. The system has been …

Relative output factor and beam profile measurements of small radiation fields with an L‐alanine/K‐Band EPR minidosimeter

FC Abrego, CSG Calcina, A de Almeida… - Medical …, 2007 - Wiley Online Library
The performance of an L‐alanine dosimeter with millimeter dimensions was evaluated for
dosimetry in small radiation fields. Relative output factor (ROF) measurements were made …

Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry

CSG Calcina, A de Almeida, JRO Rocha… - Physics in Medicine …, 2005 - iopscience.iop.org
Source positioning close to the tumour in high dose rate (HDR) brachytherapy is not
instantaneous. An increment of dose will be delivered during the movement of the source in …

Response of L-alanine and 2-methylalanine minidosimeters for K-Band (24 GHz) EPR dosimetry

F Chen, CFO Graeff, O Baffa - Nuclear Instruments and Methods in Physics …, 2007 - Elsevier
Minidosimeters of l-alanine and 2-methylalanine (2MA) were prepared and tested as
potential candidates for small radiation field dosimetry. To quantify the free radicals created …

Rapid scan electron paramagnetic resonance at 1.0 áGHz of defect centers in γ-irradiated organic solids

Y Shi, GA Rinard, RW Quine, SS Eaton… - Radiation …, 2016 - Elsevier
The radicals in six 60 Co γ-irradiated solids: malonic acid, glycylglycine, 2, 6 di-t-butyl 4-
methyl phenol, l-alanine, dimethyl malonic acid, and 2-amino isobutyric acid, were studied …

EPR of gamma-irradiated polycrystalline alanine-in-glass dosimeter

AM Al-Karmi, MA Morsy - Radiation measurements, 2008 - Elsevier
This study attempts to overcome some of the reported discrepancies in alanine-EPR
reproducibility that may be related to alanine dosimeter preparation and/or EPR …

Small radiation field dosimetry with 2-methylalanine miniature dosimeters at K-band electron paramagnetic resonance

F Chen, CSG Calcina, A de Almeida… - Radiation …, 2007 - Elsevier
Minidosimeters of 2-methyalanine (2MA) with millimeter dimensions were produced and
tested for small radiation field dosimetry. Their performance was assessed by measuring the …

Atividade Antioxidante de extratos vegetais da flora brasileira: Estudo com ressonância paramagnética eletrônica (RPE) e teoria do funcional da densidade (TFD)

AB Santos - 2006 - teses.usp.br
Há, no Brasil, uma enorme diversidade de espécies vegetais, e um conhecimento popular
de várias propriedades medicinais das mesmas. Dentre os estudos realizados com extratos …

[PDF][PDF] ESR dosimetry

O Baffa, A Kinoshita, F Chen Abrego… - AIP Conference …, 2004 - researchgate.net
ESR dosimetry is widely used for several applications such as dose assessment in
accidents, medical applications and sterilization of food and other materials. In this work the …

Estudos dosimétricos em interfaces teciduais em radioterapia utilizando dosimetria por ressonância paramagnética eletrônica EPR

JLJV Ramirez - 2010 - teses.usp.br
A acurácia e precisão exigida nas novas técnicas radioterápicas é bastante elevada, como
no caso da Radioterapia com Intensidade Modulada (IMRT). Desta forma, o tamanho dos …