Critical angle reflection imaging for quantification of molecular interactions on glass surface

G Ma, R Liang, Z Wan, S Wang - Nature communications, 2021 - nature.com
Quantification of molecular interactions on a surface is typically achieved via label-free
techniques such as surface plasmon resonance (SPR). The sensitivity of SPR originates …

Osmotic Pressure and Its Biological Implications

S Zheng, Y Li, Y Shao, L Li, F Song - International Journal of Molecular …, 2024 - mdpi.com
Gaining insight into osmotic pressure and its biological implications is pivotal for revealing
mechanisms underlying numerous fundamental biological processes across scales and will …

Alternative and simple method to determine the refractive index of human dentin

R Márquez-Islas, D Mendiola-Rojas… - Review of Scientific …, 2024 - pubs.aip.org
Determining a substance's refractive index (RI) is of great importance in a wide variety of
disciplines, such as chemistry, biomedicine, engineering, and optics, to name just a few …

Comparison of sample preparation methods, validation of an UPLC–MS/MS procedure for the quantification of cyclosporine A in whole blood sample

L Wu, Z Ye, X Zhang, Y Cheng, L Zheng, H Qiu… - … of Pharmaceutical and …, 2021 - Elsevier
Current main methods for therapeutic drug monitoring (TDM) of cyclosporine A (CsA) are
immunoassays and liquid chromatography tandem mass spectrometry. The sample …

Unambiguous derivation of the effective refractive index of biological suspensions and an extension to dense tissue such as blood

A Nahmad-Rohen, A García-Valenzuela - JOSA A, 2021 - opg.optica.org
The van de Hulst formula provides an expression for the effective refractive index or effective
propagation constant of a suspension of particles of arbitrary shape, size, and refractive …

Functional refractive-index sensor by internal reflection of diffuse light

D Pineda-Vázquez, A García-Valenzuela - Sensor Review, 2022 - emerald.com
Purpose This study aims to propose and study a refractive index sensor based on
measuring variations of the internal diffuse reflectance from a glass interface in a functional …

An efficient analysis of oblique reflection of airborne ultrasound beams from thin membranes for gas sensing

A Ortega-Aguilar, R Velasco-Segura… - The Journal of the …, 2022 - pubs.aip.org
The use of the angular spectrum method (ASM) to simulate the reflection of airborne
ultrasound beams from a thin membrane separating air from a mixture of air and another gas …

Analysis of wavelength-scale 1D depth-dependent refractive-index gradients at an interface by their effects on the internal reflectance near the critical angle

O Vázquez-Estrada, A Acevedo-Barrera… - Optics Letters, 2021 - opg.optica.org
Light's internal reflectivity near a critical angle is very sensitive to the angle of incidence and
the optical properties of the external medium near the interface. Novel applications in …

Erythrocytes' osmotic fragility test with a standard Abbe refractometer

A Pérez-Pacheco, LB Salazar-Nieva… - Revista médica del …, 2020 - scielo.org.mx
PEREZ-PACHECO, Argelia et al. Erythrocytes' osmotic fragility test with a standard Abbe
refractometer. Rev. med. Hosp. Gen. Méx.[online]. 2020, vol. 83, n. 1, pp. 20-25. Epub 06 …

Probing bio-tissue films by optical internal reflectivity: modeling and measurements

A Acevedo-Barrera, A García-Valenzuela - Applied Optics, 2021 - opg.optica.org
In this paper, we develop a detailed theoretical model for the optical reflectivity of a bio-
tissue film confined between two flat interfaces based on the anomalous-diffraction …