Emerging technologies for image guidance and device navigation in interventional radiology

GC Kagadis, K Katsanos, D Karnabatidis… - Medical …, 2012 - Wiley Online Library
Recent developments in image‐guidance and device navigation, along with emerging
robotic technologies, are rapidly transforming the landscape of interventional radiology (IR) …

[HTML][HTML] Implementation of material decomposition using an EMCCD and CMOS-based micro-CT system

AR Podgorsak, SVS Nagesh… - Proceedings of SPIE …, 2017 - ncbi.nlm.nih.gov
This project assessed the effectiveness of using two different detectors to obtain dual-energy
(DE) micro-CT data for the carrying out of material decomposition. A micro-CT coupled to …

Image acquisition, geometric correction and display of images from a 2x2 x-ray detector array based on electron multiplying charge coupled device (EMCCD) …

SNS Vasan, P Sharma, CN Ionita… - … 2013: Physics of …, 2013 - spiedigitallibrary.org
A high resolution (up to 11.2 lp/mm) x-ray detector with larger field of view (8.5 cm x 8.5 cm)
has been developed. The detector is a 2 x 2 array of individual imaging modules based on …

Investigation of noise and contrast sensitivity of an electron multiplying charge-coupled device (EMCCD) based cone beam micro-CT system

SB Krishnakumar, AR Podgorsak… - … 2016: Physics of …, 2016 - spiedigitallibrary.org
A small animal micro-CT system was built using an EMCCD detectors having complex pre-
digitization amplification technology, high-resolution, high-sensitivity and low-noise. Noise in …

Quantitative analysis of an enlarged area Solid State X-ray Image Intensifier (SSXII) detector based on Electron Multiplying Charge Coupled Device (EMCCD) …

SNS Vasan, P Sharma, V Singh, A Jain… - … 2013: Physics of …, 2013 - spiedigitallibrary.org
Present day treatment for neurovascular pathological conditions involves the use of devices
with very small features such as stents, coils, and balloons; hence, these interventional …

[图书][B] Evaluation of performance of various high resolution x-ray imaging detectors

V Singh - 2014 - search.proquest.com
The basic concepts that are used to describe the performance of an x-ray detector regarding
intrinsic image quality are sharpness, contrast, noise and signal-to-noise (SNR) ratio. The …

Implementation of digital multiplexing for high resolution x-ray detector arrays

P Sharma, SNS Vasan, AH Titus… - … Conference of the …, 2012 - ieeexplore.ieee.org
We describe and demonstrate for the first time the use of the novel Multiple Module
Multiplexer (MMMIC)[1] for a 2× 2 array of new electron multiplying charge coupled device …

Evaluation of CT Image Quality of a Cone Beam Micro-CT system with Electron Multiplying CCD

SB Krishnakumar - 2016 - search.proquest.com
A small animal imaging Micro-CT system was built using an EMCCD detector. EMCCD
detectors have a pre-digitization amplification technology, high-resolution, high-sensitivity …

Intrinsic and total system performance evaluation for a newly developed Solid State X-ray Image Intensifier (SSXII) detector

V Singh, SNS Vasan, A Jain, P Sharma… - … 2013: Physics of …, 2013 - spiedigitallibrary.org
The new Solid State X-ray Image Intensifier (SSXII) is a high-resolution, high-sensitivity, real-
time region-ofinterest (ROI) x-ray imaging detector. Evaluations were made of both standard …

A 2× 2 array of EMCCD-based solid state x-ray detectors

P Sharma, SNS Vasan, AH Titus… - … Conference of the …, 2012 - ieeexplore.ieee.org
We have designed and developed a new solid-state x-ray imaging system that consists of a
2× 2 array of electron multiplying charge coupled devices (EMCCDs). This system is …