[图书][B] The electric power engineering handbook-five volume set

LL Grigsby - 2018 - taylorfrancis.com
The Electric Power Engineering Handbook, Third Edition updates coverage of recent
developments and rapid technological growth in crucial aspects of power systems, including …

Comparison between suppressing approaches of very fast transients in gas-insulated substations (GIS)

A Tavakoli, A Gholami, H Nouri… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
In this paper, first transient waves in the gas-insulated substation (GIS) are analyzed and
methods for suppression of very fast transients (VFTs) in GISs are introduced. For …

A model of electromagnetic interferences induced by corona discharges for wireless channels in substation environments

M Au, BL Agba, F Gagnon - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
The design of robust receivers in environments with strong impulsive noise may be
challenging due to their high-amplitude events and their rare but nonnegligible occurrence …

Measurement of multipath transients in secondary cables near a 500 kV gas-insulated switchgear during operations

Z Liu, Y Cui, B Zhang, J He - IEEE Transactions on Power …, 2022 - ieeexplore.ieee.org
Operation of SF 6 gas-insulated switchgear (GIS) produces very fast transient overvoltage,
which may interfere with the secondary system through many paths. As more and more …

Mitigation of transient ground potential rise in gas insulated substations during very fast transient overvoltage

M Alexandru, L Czumbil, A Polycarpou, H Nouri… - Electric Power Systems …, 2022 - Elsevier
This paper is focused on the assessment and mitigation of the transient response of a Gas
Insulated Substation's (GIS) grounding grid to the fault due to voltage breakdown using the …

Calculation of power system overvoltages

JA Martinez‐Velasco… - Transient analysis of …, 2015 - Wiley Online Library
This chapter presents a short description of the main causes and methods for limitation of
overvoltages. It discusses the analysis and calculation of typical overvoltages. The chapter …

Characteristics of very fast transient currents in ultra high-voltage power system with Hybrid reactive power compensation

H Liu, T Chen, Q Sun, M Han, Q Li, WH Siew - International Journal of …, 2018 - Elsevier
Hybrid reactive power compensation (HRPC) consists of a stepped controlled shunt reactor
(SCSR) and a series compensation (SC), which will find applications in future ultra high …

[PDF][PDF] Possibilities and limitations of radio-frequency measurement of arc duration in HVAC circiut breakers

MA Chapman - 2011 - research-collection.ethz.ch
Economic pressures have led to the increasing application of conditionbased maintenance
to high-voltage AC (HVAC) circuit breakers. The effort of condition monitoring is not justified …

[引用][C] 500kV 气体绝缘变电站开关操作对智能组件电流互感器端口电磁骚扰的实测及分析

刘骁繁, 崔翔, 吴恒天, 嵇建飞, 焦重庆 - 高电压技术, 2015

[引用][C] GIS 隔离开关操作过程中管壳空间暂态电磁辐射计算

干喆渊, 赵军, 张建功, 谢鹏康, 陈恒林 - 高电压技术, 2016