Development and characterisation of a controllable adjustable knee joint mechanism

M Olinski, A Gronowicz, M Ceccarelli - Mechanism and Machine Theory, 2021 - Elsevier
The paper focuses on the development of a new adjustable knee joint mechanism that can
also be used as a device to assist in the rehabilitation of knee joint motion. The mechanism …

Knee joint prototype based on cam mechanism–design and video analysis

M Olinski - Computer Methods in Biomechanics and Biomedical …, 2023 - Taylor & Francis
The paper is focused on a design of mechanism accurately reproducing a complex motion in
the sagittal plane of a human knee joint. The desired movement is modelled by applying …

Continuous passive motion machine for elbow rehabilitation

HHM Al-Almoodi, NZ Azlan, I Shahdad… - … Journal of Robotics …, 2021 - pubs2.ascee.org
Continuous passive motion (CPM) treatment is widely used in treating patients after various
joint surgeries [1]-[8] to avoid joint stiffness and improve patient's recovery. It enhances the …

The Use of Generative Design Methods to Reduce the Parameters of an Actuator Used in the Positioning System of a Continuous Passive Motion (CPM) Device

R Trochimczuk, A Zdobytskyi, P Borkowski - Applied Sciences, 2024 - mdpi.com
This paper presents the results of a computer optimising a multibody system using
Generative Design methods to select a lower-cost actuator that meets process requirements …

Design And Development of Integrated Knee and Ankle Continuous Passive Motion Machine

L Dhiviyalakshmi, RL Sowndari… - … on Integration of …, 2023 - ieeexplore.ieee.org
Sports-related and common injuries affecting the knee and ankle may result in excruciating
pain, mobility loss, and other symptoms. Continuous passive motion (CPM) devices have …

Estimation of Tibiofemoral Joint Contact Forces Using Foot Loads during Continuous Passive Motions

Y Yang, H Huang, J Guo, F Yu, Y Yao - Sensors, 2022 - mdpi.com
Continuous passive motion (CPM) machines are commonly used after various knee
surgeries, but information on tibiofemoral forces (TFFs) during CPM cycles is limited. This …

[PDF][PDF] Jurnal Polimesin

A Nugroho, F Lumela, RD Ratnani - researchgate.net
Biodiesel is one of the efforts to reduce dependence on fuel oil developed as an
environmentally friendly alternative fuel in Indonesia. The addition of coconut shell oil will …

[引用][C] Static Continuous Passive Motion (CPM) Machine Simulation Tackle Therapy with SolidWorks

FKA Nugraha, AH Noviyanto, BL Anurogo - Jurnal Polimesin, 2023