Infrared thermography for assessing moisture related phenomena in building components

E Barreira, R Almeida, J Delgado - Construction and building materials, 2016 - Elsevier
In this work the potential of infrared thermography (IRT) to assess moisture related
phenomenon was tested. Initially, several set-ups and boundary conditions were created to …

An infrared thermography passive approach to assess the effect of leakage points in buildings

E Barreira, RMSF Almeida, M Moreira - Energy and Buildings, 2017 - Elsevier
Energy consumption is one of the major concerns of European citizens and governments. In
the EU, buildings use 40% of total energy consumption and generate 36% of greenhouse …

A discussion concerning active infrared thermography in the evaluation of buildings air infiltration

C Lerma, E Barreira, RMSF Almeida - Energy and buildings, 2018 - Elsevier
The EU is strongly committed to energy saving in buildings. Air leaks through the building
envelope represent a significant percentage of buildings energy consumption. Locating and …

Moisture damage in ancient masonry: a multidisciplinary approach for in situ diagnostics

N Proietti, P Calicchia, F Colao, S De Simone… - Minerals, 2021 - mdpi.com
San Nicola in Carcere, one of the minor basilicas in the historical center of Rome, was the
location of a wide investigation campaign of the water-related deterioration causes, present …

Making decision on repointing of clay brick facades on the basis of moisture content and water absorption tests results–a review of assessment methods

SK Shahreza, M Molnár, J Niklewski… - Brick and Block …, 2020 - taylorfrancis.com
Use of clay brick masonry in façades is often motivated by its aesthetic values and durability.
Yet, mortar joints exposed to climate agents erode over time, expected to cause elevated …

Thermographic Signal Reconstruction with periodic temperature variation applied to moisture classification

P Bison, G Cadelano, E Grinzato - … InfraRed Thermography Journal, 2011 - Taylor & Francis
A method to analyse thermographic data with periodic temperature variation is proposed. A
periodic heat flux is generated on the surface of a specimen with a non-zero average value …

Monitoring Moisture Diffusion after Contact Sponge Application

P Bison, G Cadelano, G Ferrarini, M Girotto… - Engineering …, 2023 - mdpi.com
The contact sponge method is applied on a piece of clay brick. According to the standard,
the sponge is moistened with water, applied on the surface of the material by means of a …

Use of holographic subsurface radar analysis in the preservation and restoration of cultural heritage objects

S Ivashov, L Capineri, T Bechtel… - Surface Topography …, 2019 - iopscience.iop.org
Traditionally, the same non-destructive testing technologies which are used in industry and
engineering applications are applicable in diagnostics of cultural heritage objects and …

A new sensorized ceramic plug for the remote monitoring of moisture in historic masonry walls: First results from laboratory and onsite testing

E Franzoni, M Bassi - Structural Control and Health Monitoring, 2022 - Wiley Online Library
The presence of moisture in historic buildings, especially from rising damp, is extremely
widespread and severe, causing materials' deterioration, internal discomfort and bad …

Advancement of infrared thermography for built heritage

E Rosina, M Kavuru, EI Parisi - Diagnosis of Heritage Buildings by Non …, 2024 - Elsevier
Thermal imaging of buildings and historical structures of the diffuse historical heritage make