IDeF-X ECLAIRs: A CMOS ASIC for the readout of CdTe and CdZnTe detectors for high resolution spectroscopy

O Gevin, P Baron, X Coppolani, FÇ Daly… - … on Nuclear Science, 2009 - ieeexplore.ieee.org
The very last member of the IDeF-X ASIC family is presented: IDeF-X ECLAIRs is a 32-
channel front end ASIC designed for the readout of Cadmium Telluride (CdTe) and …

IDeF-X HD: A low power multi-gain CMOS ASIC for the readout of Cd (Zn) Te detectors

A Michalowska, O Gevin, O Lemaire… - … & Medical Imaging …, 2010 - ieeexplore.ieee.org
Since few years, our group is developing a family of ASICs for space applications, named
IDeF-X for Imaging Detector Front-end. IDeF-X HD is the new member of the IDeF-X family. It …

IDeF-X HD: a CMOS ASIC for the readout of Cd (Zn) Te Detectors for space-borne applications

O Gevin, O Limousin, F Lugiez… - Journal of …, 2021 - World Scientific
IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the
readout of 1 6× 1 6 pixels CdTe or CdZnTe pixelated detectors to build a low power micro …

IDeF-X ECLAIRs: An ultra low noise CMOS ASIC for the readout of Cd (Zn) Te detectors

O Gevin, P Baron, X Coppolani… - 2007 IEEE Nuclear …, 2007 - ieeexplore.ieee.org
The very last member of the IDeF-X ASIC family is presented: IDeF-X ECLAIRs is a 32-
channel front end ASIC designed for the readout of low capacitive (2 to 5 pF) and low …

Caliste 64, an innovative cdte hard x-ray micro-camera

A Meuris, O Limousin, F Lugiez, O Gevin… - … on Nuclear Science, 2008 - ieeexplore.ieee.org
A prototype 64 pixel miniature camera has been designed and tested for the Simbol-X hard
X-ray observatory to be flown on the joint CNES-ASI space mission in 2014. This device is …

Design of a Low-Noise Photon-Count Readout ASIC for Si-PIN-Based Personal Dosimeters With Low Energy Detection Threshold

W Gao, T Gao, L Sun, C Zhao, J Zhou… - IEEE Transactions …, 2023 - ieeexplore.ieee.org
A portable electronic personal dosimeter (EPD) with a battery supply is widely used to
monitor the dose equivalence of staff in nuclear radiation environments, requiring both a low …

IDeF-X V1. 1: Performances of a new CMOS 16 channels analogue readout ASIC for Cd (Zn) Te detectors

F Lugiez, O Gevin, P Baron, E Delagnes… - 2006 IEEE Nuclear …, 2006 - ieeexplore.ieee.org
A new full custom readout ASIC is presented. Its name is IDeF-X V1. 1 for imaging detector
front-end. The actual version of the IDeF-X ASIC is a complete 16 channels analogue front …

Measurement of the transverse diffusion coefficient of charge in liquid xenon

WT Chen, H Carduner, JP Cussonneau… - Defect and Diffusion …, 2012 - Trans Tech Publ
Liquid xenon (LXe) is a very attractive material as a detection medium for ionization
detectors due to its high density, high atomic number, and low energy required to produce …

Development of a readout electronic for the measurement of ionization in liquid xenon compton telescope containing micro-patterns

O Lemaire, WT Chen, JP Cussonneau… - 2012 IEEE Nuclear …, 2012 - ieeexplore.ieee.org
We report on the electronic dedicated to the acquisition of the ionization current signal
induced by the interactions of γ-rays inside a Compton telescope with Liquid Xenon. In order …

Détecteur liquide multipixellisé, pour l'imagerie médicale et préclinique

X Mancardi - 2016 - theses.hal.science
Le projet CaLIPSO (Calorimètre Liquide Ionisation Position Scintillation Organométallique)
a pour ambition de mettre au point un détecteur de γ 511 keV très efficace et très rapide …