Real‐time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self‐tuning filter

S Biricik, S Redif, ÖC Özerdem… - IET Power …, 2014 - Wiley Online Library
In this paper, an alternative control method is proposed to improve the harmonic
suppression efficiency of the active power filter in a distorted and an unbalanced power …

Adaptive notch filter solution under unbalanced and/or distorted point of common coupling voltage for three‐phase four‐wire shunt active power filter with sinusoidal …

ND Dinh, ND Tuyen, G Fujita… - IET Generation …, 2015 - Wiley Online Library
In this study, the three‐phase four‐wire shunt active power filter (ShAPF) dealing with non‐
ideal point of common coupling (PCC) voltages will be presented. The instantaneous power …

Harmonics mitigation and non‐ideal voltage compensation utilising active power filter based on predictive current control

M Alhasheem, P Mattavelli, P Davari - IET Power Electronics, 2020 - Wiley Online Library
It is well‐known that the presence of non‐linear loads in the distribution system can impair
the power quality. The problem becomes worse in microgrids and power electronic‐based …

A harmonic suppression method based on fractional lower order statistics for power system

Z Chen, X Geng, F Yin - IEEE Transactions on Industrial …, 2016 - ieeexplore.ieee.org
Impulse noise in power systems would seriously degrade the harmonic suppression
performance. To remedy this problem, a novel harmonic suppression method based on …

Improved harmonic suppression efficiency of single-phase APFs in distorted distribution systems

S Biricik, S Redif, SK Khadem… - International Journal of …, 2016 - Taylor & Francis
In this study, a control method is proposed to improve the harmonic suppression efficiency of
the single-phase active power filter in a distorted power system to suppress current …

Performance improvement of active power filter under distorted and unbalanced grid voltage conditions

S Biricik, OC Ozerdem, S Redif… - Elektronika ir …, 2013 - eejournal.ktu.lt
In the case of balanced and undistorted supply voltages, shunt APFs can achieve current
harmonic cancellation and give unity power factors. However, this is not possible when grid …

Novel hybrid active power filter structure to compensate harmonic currents and reactive power

S Biricik, OC Ozerdem, S Redif… - 2012 16th IEEE …, 2012 - ieeexplore.ieee.org
This research proposes a novel topology to satisfy the requirements of Harmonic
suppressing and reactive power compensation while designing HAPF. An effective strategy …

Control of the single phase parallel active filter under weak grid voltages

S Biricik, S Redif, SK Khadem… - 2014 IEEE 5th …, 2014 - ieeexplore.ieee.org
In this study, a control method is proposed to improve the harmonic suppression efficiency of
the single phase active power filter in a distorted power system environment. Here, we …

Notch adaptive filter solution under unbalanced and/or distorted PCC voltage for 3-phase 3-wire shunt active power filter

ND Tuyen, G Fujita, MNB Muhtazaruddin - Electrical Engineering, 2016 - Springer
In this paper, the 3-phase 3-wire Shunt Active Power Filter (ShAPF) dealing with non-ideal
Point of Common Coupling (PCC) voltages will be presented. The instantaneous power …

Performance evaluation of 3-phase 4-wire SAPF based on synchronizing EPLL with fuzzy logic controller

S Agrawal, D Sharma, VK Gupta… - 2018 2nd IEEE …, 2018 - ieeexplore.ieee.org
This paper work focuses on current harmonic cancelation, reactive power compensation,
neutral current compensation and power factor adjustment in a 3 phase four wire (3-ph-4w) …