The biomechanics of arterial aneurysms

JC Lasheras - Annu. Rev. Fluid Mech., 2007 - annualreviews.org
The formation of an arterial aneurysm is believed to be a multifactorial and predominantly
degenerative process, resulting from a complex interplay between biological processes in …

A review of arterial phantom fabrication methods for flow measurement using PIV techniques

SG Yazdi, PH Geoghegan, PD Docherty… - Annals of Biomedical …, 2018 - Springer
Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality in the
western world. In the last three decades, fluid dynamics investigations have been an …

Toward a better understanding of model validation metrics

Y Liu, W Chen, P Arendt, HZ Huang - 2011 - asmedigitalcollection.asme.org
Model validation metrics have been developed to provide a quantitative measure that
characterizes the agreement between predictions and observations. In engineering design …

SCENT Trial: one-year outcomes

PM Meyers, AL Coon, PT Kan, AK Wakhloo, RA Hanel - Stroke, 2019 - Am Heart Assoc
Background and Purpose—To evaluate the safety and effectiveness of the Surpass Flow
Diverter (Surpass; Stryker Neurovascular, Fremont, CA) in the treatment of large or giant …

Implantable intraluminal device and method of using same in treating aneurysms

O Yodfat, B Lieber, Y Grad, B Nishri - US Patent 7,306,624, 2007 - Google Patents
A method for reducing blood flow to an aneurysm proximate to a bifurcation having a source
blood vessel a first branch vessel and a second branch vessel, the method comprising …

Effect of flow diverter porosity on intraaneurysmal blood flow

L Augsburger, M Farhat, P Reymond, E Fonck… - Clinical …, 2009 - doc.rero.ch
Background and Purpose:: Growth and rupture, the two events that dominate the evolution of
an intracranial aneurysm, are both dependent on intraaneurysmal flow. Decrease of …

Validation of CFD simulations of cerebral aneurysms with implication of geometric variations

Y Hoi, SH Woodward, M Kim, DB Taulbee, H Meng - 2006 - asmedigitalcollection.asme.org
Background. Computational fluid dynamics (CFD) simulations using medical-image-based
anatomical vascular geometry are now gaining clinical relevance. This study aimed at …

Comparison of two stents in modifying cerebral aneurysm hemodynamics

M Kim, DB Taulbee, M Tremmel, H Meng - Annals of biomedical …, 2008 - Springer
There is a general lack of quantitative understanding about how specific design features of
endovascular stents (struts and mesh design, porosity) affect the hemodynamics in …

Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms

G Cantón, DI Levy, JC Lasheras, PK Nelson - Journal of neurosurgery, 2005 - thejns.org
Object. The goal of this study was to quantify the reduction in velocity, vorticity, and shear
stresses resulting from the sequential placement of stents across the neck of sidewall …

Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model—a report on the Virtual Intracranial Stenting Challenge 2007

AG Radaelli, L Augsburger, JR Cebral, M Ohta… - Journal of …, 2008 - Elsevier
This paper presents the results of the Virtual Intracranial Stenting Challenge (VISC) 2007, an
international initiative whose aim was to establish the reproducibility of state-of-the-art …