Rehabilitation of existing structures in seismic zones

C Bob - Progress in structural Engineering and Materials, 2001 - Wiley Online Library
Existing structures built before the 1970s are gravity load designed with inadequate lateral
load resistance because earlier codes specified lower levels of seismic loads and many of …

[PDF][PDF] New Techniques for Rehabilitation of Masonry Structures

C Bob, L Bob, V Florea, A Gruin - IABSE Symposium Report, 2005 - academia.edu
The paper presents the rehabilitation methods for masonry structures. In the first part, an
experimental programe concerning the technical efficiency of the masonry strengthening …

[PDF][PDF] Solutions for Bond Improving of Reinforced Concrete Columns Jacketing

C Enuica, C Bob, S Dan, C Badea… - Proceedings of the 11th …, 2009 - researchgate.net
The paper deals with the results and design conclusions based on an experimental
programme and its application to a structural rehabilitation. The experimental programme …

[PDF][PDF] The Influence Of Foundation Soils Concernig The Behaviour Of Buildings

M Tudorică, C Bob - Journal of Applied Engineering Sciences, 2015 - sciendo.com
An issue more and more important in construction science represents the rehabilitation of
structures placed on difficult soils. This paper presents the behaviour analysis of an existing …

[PDF][PDF] Modern solutions for strengthening of masonry structures

S DAN, C BOB, L BOB, A GRUIN… - 11th WSEAS International …, 2009 - academia.edu
The paper presents the rehabilitation methods for masonry structures. In the first part, an
experimental programme concerning the technical efficiency of the masonry strengthening …

[PDF][PDF] Assessment and Strengthening of Existing RC Framed Structures

S Dan, C Bob, C Badea - Extras din Buletinul Institutului Politehnic …, 2006 - researchgate.net
The vulnerability of existing structures may be due to structural system weaknesses and
specific detailing. Structural weaknesses are characterised by various irregularities and …

[PDF][PDF] Modern Solutions for Strengthening of Structural Elements

DAN Sorin, BOB Corneliu, C ENUICA, BOB Liana… - researchgate.net
The paper deals with the results and recommendations based on experimental
programmes. The first experimental programme presents the strengthening effect of RC …

[PDF][PDF] Repair and Renewal of Existing Structures in Seismic Zones

BOB Corneliu, DAN Sorin - researchgate.net
Existing structures built before 1970s are gravity load designed with inadequate lateral load
resistance because earlier codes specified lower levels of seismic loads and many of these …

[PDF][PDF] Refurbishment of Old Buildings by Classic and Modern Technologies

BOB Corneliu, DAN Sorin, C BADEA, A GRUIN - researchgate.net
Refurbishment of Old Buildings by Classic and Modern Technologies Summary 1. Introduction
2. Experimental programme Page 1 Refurbishment of Old Buildings by Classic and Modern …

[PDF][PDF] STRUCTURAL REHABILITATION OF HISTORICAL MASONRY BUILDINGS IN ROMANIA

S Dan - academia.edu
The paper is focused on the analysis, redesign and rehabilitation solutions applied for old
existing structures in seismic zones. The old malting building, erected between 1857-1876 …