Direct electron transfer between copper-containing proteins and electrodes

S Shleev, J Tkac, A Christenson, T Ruzgas… - Biosensors and …, 2005 - Elsevier
The electrochemistry of some copper-containing proteins and enzymes, viz. azurin,
galactose oxidase, tyrosinase (catechol oxidase), and the “blue” multicopper oxidases …

Peroxidase-modified electrodes: fundamentals and application

T Ruzgas, E Csöregi, J Emnéus, L Gorton… - Analytica Chimica …, 1996 - Elsevier
Peroxidase-modified amperometric electrodes have been widely studied and developed,
not only because of hydrogen-and organic peroxides are important analytes but also …

Telemetered characteristic monitor system and method of using the same

AE Mann, RE Purvis, JJ Mastrototaro… - US Patent …, 2006 - Google Patents
(57) ABSTRACT A telemetered characteristic monitor system includes a remotely located
data receiving device, a sensor for produc ing signal indicative of a characteristic of a user …

Remote monitoring for networked fluid infusion systems

SB Moberg, KJ Long, KJ Mehta, IB Hanson - US Patent 7,942,844, 2011 - Google Patents
(58) Field of Classi? cation Search 60 4/6 5* 67 A? uid infusion system as described herein
includes a number of local “body network” devices, such as an infusion pump, a handheld …

Coordination of control commands in a medical device system having at least one therapy delivery device and at least one wireless controller device

SB Moberg, IB Hanson - US Patent 8,344,847, 2013 - Google Patents
4,559,037 4,562,751 4,671,288 4,678.408 4,685,903 4,731,051 4,731,726 4,781,798
4,803,625 4,809,697 4,826,810 4,871,351 4,898,578 5,003.298 5,011,468 5,019,974 …

Direct electron transfer between heme-containing enzymes and electrodes as basis for third generation biosensors

L Gorton, A Lindgren, T Larsson, FD Munteanu… - Analytica Chimica …, 1999 - Elsevier
Direct electron transfer (DET) between redox enzymes and electrodes found the basis for
third generation biosensors. Recent investigations in the authors' laboratories on the …

Hydrogen peroxide sensor based on horseradish peroxidase-labeled Au colloids immobilized on gold electrode surface by cysteamine monolayer

Y Xiao, HX Ju, HY Chen - Analytica Chimica Acta, 1999 - Elsevier
A novel strategy to construct a sensitive amperometric sensor of H2O2 was described.
Horseradish peroxidase (HRP) was successfully immobilized on nanometer-sized Au …

A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized on colloidal Au modified ITO electrode

L Wang, E Wang - Electrochemistry Communications, 2004 - Elsevier
A novel method to fabricate a hydrogen peroxide sensor was developed by immobilizing
horseradish peroxidase (HRP) on colloidal Au modified ITO conductive glass support. The …

Hydrogen peroxide and. beta.-nicotinamide adenine dinucleotide sensing amperometric electrodes based on electrical connection of horseradish peroxidase redox …

M Vreeke, R Maidan, A Heller - Analytical Chemistry, 1992 - ACS Publications
Hydrogen peroxide and .beta.-nicotinamide adenine dinucleotide sensing amperometric
electrodes based on electrical connection of Page 1 3084 Anal. Chem. 1992, 64, 3084-3090 …

Subnetwork synchronization and variable transmit synchronization techniques for a wireless medical device network

KJ Mehta, JJ Mika III - US Patent 8,073,008, 2011 - Google Patents
(57) ABSTRACT A fluid infusion system as described herein includes a number of local
“body network devices, such as an infusion pump, a handheld monitor or controller, a …