Precision luminosity measurement in proton–proton collisions at s√= 13TeV in 2015 and 2016 at CMS

CMs Collaboration - 2021 - Springer
Precision luminosity measurement in proton–proton collisions at in 2015 and 2016 at CMS
Page 1 Eur. Phys. J. C (2021) 81:800 https://doi.org/10.1140/epjc/s10052-021-09538-2 Regular …

Precision luminosity measurement in proton–proton collisions at in 2015 and 2016 at CMS

AM Sirunyan, A Tumasyan, W Adam… - The European Physical …, 2021 - Springer
The measurement of the luminosity recorded by the CMS detector installed at LHC
interaction point 5, using proton–proton collisions at s= 13 TeV s= 13 TeV in 2015 and 2016 …

[HTML][HTML] Beam feasibility study of a collimator with in-jaw beam position monitors

D Wollmann, AA Nosych, G Valentino, O Aberle… - Nuclear Instruments and …, 2014 - Elsevier
At present, the beam-based alignment of the LHC collimators is performed by touching the
beam halo with both jaws of each collimator. This method requires dedicated fills at low …

LHC luminosity performance

M Hostettler - 2018 - cds.cern.ch
This thesis adresses several approaches with the common goal of assessing, understanding
and improving the luminosity of the Large Hadron Collider (LHC). To better exploit existing …

First operational experience with the LHC Diode ORbit and OScillation (DOROS) system

M Gasior, G Baud, J Olexa, G Valentino - 2016 - um.edu.mt
The LHC started high-energy operation in 2015 with new tertiary collimators, equipped with
beam position monitors embedded in their jaws. The required resolution and stability of the …

Faraday cup award: High sensitivity tune measurement using direct diode detection

M Gasior - Conf. Proc., 2012 - cds.cern.ch
Abstract Direct Diode Detection (3D) is a technique developed at CERN initially for the LHC
tune measurement system, to reach a sensitivity allowing observation of beam betatron …

First operational experience with embedded collimator BPMs in the LHC

G Valentino, G Baud, R Bruce, M Gasior, J Olexa… - 2016 - um.edu.mt
During Long Shutdown 1, 18 Large Hadron Collider (LHC) collimators were replaced with a
new design, in which beam position monitor (BPM) pick-up buttons are embedded in the …

Direct (under) Sampling vs. Analog Downconversion for BPM Electroncs

M Wendt - 2014 - cds.cern.ch
Digital signal processing by means of undersampling the analog signal has become a
popular method for acquiring beam position monitor signals. This presentation discusses the …

Experimental Demonstration of β* Leveling at the LHC

A Gorzawski, B Salvachua, D Mirarchi, J Wenninger - 2016 - cds.cern.ch
The HL-LHC project foresees to boost the LHC peak luminosity beyond the capabilities of
the LHC experimental detectors. Leveling the luminosity down to a constant value that is …

[PDF][PDF] Development and beam tests of an automatic algorithm for alignment of LHC collimators with embedded BPMs

G Valentino, R Bruce, M Gasior, D Mirarchi, AA Nosych… - 2013 - um.edu.mt
Collimators with embedded Beam Position Monitor (BPM) buttons will be installed in the
LHC during the upcoming long shutdown period. During the subsequent operation, the …