ESR dosimetry with lithium, potassium, and sodium compounds

AB Rech, A Kinoshita, PM Donate, O Baffa - Applied Radiation and …, 2022 - Elsevier
This work consists of a first investigation of materials that could be used as ESR dosimeters
with doses up to 5 Gy aiming possible applications that would include retrospective …

ESR dosimeter material properties of phenols compound exposed to radiotherapeutic electron beams

S Gallo, G Iacoviello, A Bartolotta, D Dondi… - Nuclear Instruments and …, 2017 - Elsevier
There is a need for a sensitive dosimeter using Electron Spin Resonance spectroscopy for
use in medical applications, since non-destructive read-out and dose archival could be …

Numerical analysis of the alanine response using Monte Carlo: Correlation with experimental results

F Rouihem, F Hosni, W Dridi, M Daoudi, P Blaise… - Radiation Physics and …, 2022 - Elsevier
International centers based on research reactors (ICERR) project supported by IAEA, offers
training and research in the application of advanced nuclear reactor technology. In this …

Cumulative dose experiments on Lithium formate monohydrate as an EPR-dosimeter for use in different radiation therapy scenarios

A Belahmar, M Mikou, C Hoehr, M El Ghalmi - Nuclear Instruments and …, 2022 - Elsevier
Abstract The Electron Paramagnetic Resonance (EPR) method can be employed to read out
the absorbed dose of suitable materials exposed to ionizing radiation. In this work, we study …

Characterization of improved PASSAG polymer gel dosimeter using magnetic resonance imaging

M Dorri Giv, M Majdaeen, M Yadollahi… - Applied Magnetic …, 2022 - Springer
Abstract Poly 2-acrylamido-2-methy-1-propanesulfonic acid sodium salt and gelatin
(PASSAG) gel dosimeter has a negligible toxicity and also excellent dosimetric …

Dosimetric properties of PASSAG polymer gel dosimeter in electron beam radiotherapy using magnetic resonance imaging

T Zhang, YQ Almajidi, SA Awad… - Journal of X-ray …, 2023 - content.iospress.com
BACKGROUND: Several physical factors such as photon beam energy, electron beam
energy, and dose rate may affect the dosimetric properties of polymer gel dosimeters. The …

The investigation of dose rate and photon beam energy dependence of optimized PASSAG polymer gel dosimeter using magnetic resonance imaging

B Liu, S Haithem Zaki, E García… - Journal of X-Ray …, 2024 - content.iospress.com
OBJECTIVE: It seems that dose rate (DR) and photon beam energy (PBE) may influence the
sensitivity and response of polymer gel dosimeters. In the current project, the sensitivity and …

A dual natural lithium formate/L-alanine EPR dosimeter for a mixed radiation field in a boron neutron capture therapy irradiation facility

G Alejandro, J Longhino, NR Alvarez… - Journal of Physics D …, 2020 - iopscience.iop.org
Standard commercial L-alanine pellets and specially prepared natural lithium formate
monohydrate powder samples of specific granulometry were irradiated in a 60 Co gamma …

Improvement of neutron sensitivity for lithium formate EPR dosemeters: a Monte Carlo analysis

MC D'Oca, G Collura, C Gagliardo… - Radiation Protection …, 2023 - academic.oup.com
This work presents the computational analysis of the sensitivity improvements that could be
achieved in lithium formate monohydrate (LFM) electron paramagnetic resonance (EPR) …

Alanine pellets comparison using EPR dosimetry in the frame of quality assurance for a Gamma Knife system in Romania

CS Tuta, MN Amiot, L Sommier, RM Ioan - Radiation Physics and Chemistry, 2020 - Elsevier
In the last decade, the use of alanine/Electronic Paramagnetic Resonance (EPR) system
was extended to radiotherapy doses. In stereotactic radiosurgery, doses up to 70 Gy are …