Rapid estimation of 2D relative B 1+‐maps from localizers in the human heart at 7T using deep learning

F Krueger, CS Aigner, K Hammernik… - Magnetic …, 2023 - Wiley Online Library
Purpose Subject‐tailored parallel transmission pulses for ultra‐high fields body applications
are typically calculated based on subject‐specific B 1+ B _1^+‐maps of all transmit …

Rapid 3D absolute B1+ mapping using a sandwiched train presaturated TurboFLASH sequence at 7 T for the brain and heart

JL Kent, I Dragonu, L Valkovič… - Magnetic Resonance in …, 2023 - Wiley Online Library
Purpose To shorten the acquisition time of magnetization‐prepared absolute transmit field
(B1+) mapping known as presaturation TurboFLASH, or satTFL, to enable single breath …

Whole‐liver flip‐angle shimming at 7 T using parallel‐transmit kT‐point pulses and Fourier phase‐encoded DREAM mapping

BA Runderkamp, T Roos… - Magnetic resonance …, 2024 - Wiley Online Library
Purpose To obtain homogeneous signal throughout the human liver at 7 T. Flip angle (FA)
shimming in 7T whole‐liver imaging was performed through parallel‐transmit kT‐point …

Reproducible Research Practices in Magnetic Resonance Neuroimaging: A Review Informed by Advanced Language Models

A Karakuzu, M Boudreau, N Stikov - Magnetic Resonance in Medical …, 2024 - jstage.jst.go.jp
MRI has progressed significantly with the introduction of advanced computational methods
and novel imaging techniques, but their wider adoption hinges on their reproducibility. This …

Optimized radiofrequency shimming using low-heating B1+-mapping in the presence of deep brain stimulation implants: Proof of concept

M Arianpouya, B Yang, F Tam, CE McElcheran… - PloS one, 2024 - journals.plos.org
MRI of patients with Deep Brain Stimulation (DBS) implants is constrained due to
radiofrequency (RF) heating of the implant lead. However,“RF-shimming” parallel …

Accelerated B 1+ B _1^+ mapping and robust parallel transmit pulse design for heart and prostate imaging at 7 T

N Egger, S Nagelstraßer, S Wildenberg… - Magnetic …, 2024 - Wiley Online Library
Purpose To investigate the impact of reduced k‐space sampling on B 1+ B _1^+ mapping
and the resulting impact on phase shimming and dynamic/universal parallel transmit (pTx) …

Accelerated 3D multi‐channel mapping at 7 T for the brain and heart

JL Kent, MHS de Buck, I Dragonu… - Magnetic …, 2024 - Wiley Online Library
Purpose To acquire accurate volumetric multi‐channel B 1+ B _1^+ maps in under 14 s
whole‐brain or 23 heartbeats whole‐heart for parallel transmit (pTx) applications at 7 T …

The effects of RF coils and SAR supervision strategies for clinically applicable nonselective parallel‐transmit pulses at 7 T

J Herrler, SN Williams, P Liebig, B Ding… - Magnetic …, 2023 - Wiley Online Library
Purpose To investigate the effects of using different parallel‐transmit (pTx) head coils and
specific absorption rate (SAR) supervision strategies on pTx pulse design for ultrahigh‐field …

[HTML][HTML] Improving robustness of 3D multi-shot EPI by structured low-rank reconstruction of segmented CAIPI sampling for fMRI at 7T

X Chen, W Wu, M Chiew - NeuroImage, 2023 - Elsevier
Abstract Three-dimensional (3D) encoding methods are increasingly being explored as
alternatives to two-dimensional (2D) multi-slice acquisitions in fMRI, particularly in cases …

Acceleration methods to acquire fast 3D Multi-Channel absolute B1+ maps at 7T for 8-channel pTx

JL Kent, L Valkovic, I Dragonu… - Proceedings of the 31th …, 2022 - archive.ismrm.org
Ultra-high field MRI with parallel transmit offers significant advantages but B 1 transmit maps
must be acquired to utilize its full potential. Acquiring absolute B 1+ maps for each channel …