T2 relaxation‐time mapping in healthy and diseased skeletal muscle using extended phase graph algorithms

KR Keene, JWM Beenakker… - Magnetic resonance …, 2020 - Wiley Online Library
Purpose Multi‐echo spin‐echo (MSE) transverse relaxometry mapping using multi‐
component models is used to study disease activity in neuromuscular disease by assessing …

[PDF][PDF] QMRTools: a Mathematica toolbox for quantitative MRI analysis.

M Froeling - Journal of Open Source Software, 2019 - joss.theoj.org
QMRITools is written in Mathematica using Wolfram Workbench and Eclipse and contains a
collection of tools and functions for processing quantitative magnetic resonace imaging …

Efficient simulation of ultrafast magnetic resonance experiments

L Guduff, AJ Allami, C van Heijenoort… - Physical Chemistry …, 2017 - pubs.rsc.org
Magnetic resonance spectroscopy and imaging experiments in which spatial dynamics
(diffusion and flow) closely coexists with chemical and quantum dynamics (spin–spin …

The effect of fat model variation on muscle fat fraction quantification in a cross‐sectional cohort

M Froeling, L Heskamp - NMR in Biomedicine, 2024 - Wiley Online Library
Spectroscopic imaging, rooted in Dixon's two‐echo spin sequence to distinguish water and
fat, has evolved significantly in acquisition and processing. Yet precise fat quantification …

Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla

F Fallah, J Machann, P Martirosian, F Bamberg… - … Resonance Materials in …, 2017 - Springer
Objectives To evaluate and compare conventional T1-weighted 2D turbo spin echo (TSE),
T1-weighted 3D volumetric interpolated breath-hold examination (VIBE), and two-point 3D …

Regularized joint water–fat separation with B0 map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI

Y Dong, K Koolstra, M Riedel… - Magnetic …, 2021 - Wiley Online Library
Purpose To develop a new water–fat separation and B0 estimation algorithm to effectively
suppress the multiple resonances of fat signal in EPI. This is especially relevant for DWI …

Development of a method for the Bloch image simulation of biological tissues

R Kose, K Kose, Y Terada, D Tamada… - Magnetic Resonance …, 2020 - Elsevier
Purpose The purpose of this study is to develop a method for the Bloch image simulation of
biological tissues including various chemical components and T 2* distribution. Methods …

Multi–spin echo spatial encoding provides three‐fold improvement of temperature precision during intermolecular zero quantum thermometry

RM Davis, Z Zhou, H Chung… - Magnetic resonance in …, 2016 - Wiley Online Library
Purpose Intermolecular multiple quantum coherences (iMQCs) are a source of MR contrast
with applications including temperature imaging, anisotropy mapping, and brown fat …

Effect of J coupling on 1.3‐ppm lipid methylene signal acquired with localised proton MRS at 3 T

DY Breitkreutz, BG Fallone, A Yahya - NMR in Biomedicine, 2015 - Wiley Online Library
The purpose of this work was to investigate the effect of J‐coupling interactions on the
quantification and T2 determination of 1.3‐ppm lipid methylene protons at 3 T. The response …

Intermolecular zero quantum coherences enable accurate temperature imaging in red bone marrow

RM Davis, WS Warren - Magnetic Resonance in Medicine, 2015 - Wiley Online Library
Purpose Red bone marrow metastases are common in breast and prostate cancer patients,
but those metastases are currently incurable. Recent developments show that hyperthermia …