[HTML][HTML] Safety of transcranial focused ultrasound stimulation: A systematic review of the state of knowledge from both human and animal studies

C Pasquinelli, LG Hanson, HR Siebner, HJ Lee… - Brain Stimulation, 2019 - Elsevier
Background Low-intensity transcranial focused ultrasound stimulation (TFUS) holds great
promise as a highly focal technique for transcranial stimulation even for deep brain areas …

Ultrasound for drug and gene delivery to the brain

K Hynynen - Advanced drug delivery reviews, 2008 - Elsevier
Noninvasive, transient, and local image-guided blood-brain barrier disruption (BBBD) has
been demonstrated with focused ultrasound exposure in animal models. Most studies have …

Focused ultrasound modulates region-specific brain activity

SS Yoo, A Bystritsky, JH Lee, Y Zhang, K Fischer… - Neuroimage, 2011 - Elsevier
We demonstrated the in vivo feasibility of using focused ultrasound (FUS) to transiently
modulate (through either stimulation or suppression) the function of regional brain tissue in …

Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced blood–brain barrier disruption

M Kinoshita, N McDannold… - Proceedings of the …, 2006 - National Acad Sciences
Antibody-based anticancer agents are promising chemotherapeutic agents. Among these
agents, Herceptin (trastuzumab), a humanized anti-human epidermal growth factor receptor …

Local and reversible blood–brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications

K Hynynen, N McDannold, NA Sheikov, FA Jolesz… - Neuroimage, 2005 - Elsevier
The purpose of this study was to test the hypothesis that burst ultrasound in the presence of
an ultrasound contrast agent can disrupt the blood–brain barrier (BBB) with acoustic …

Lasting blood-brain barrier disruption induces epileptic focus in the rat somatosensory cortex

E Seiffert, JP Dreier, S Ivens, I Bechmann… - Journal of …, 2004 - Soc Neuroscience
Perturbations in the integrity of the blood-brain barrier have been reported in both humans
and animals under numerous pathological conditions. Although the blood-brain barrier …

MRI-guided targeted blood-brain barrier disruption with focused ultrasound: histological findings in rabbits

N McDannold, N Vykhodtseva, S Raymond… - Ultrasound in medicine …, 2005 - Elsevier
Focused ultrasound offers a method to disrupt the blood-brain barrier (BBB) noninvasively
and reversibly at targeted locations. The purpose of this study was to test the safety of this …

Focal disruption of the blood–brain barrier due to 260-kHz ultrasound bursts: a method for molecular imaging and targeted drug delivery

K Hynynen, N McDannold, N Vykhodtseva… - Journal of …, 2006 - thejns.org
Object The goal of this study was to explore the feasibility of using low-frequency magnetic
resonance (MR) image–guided focused ultrasound as a noninvasive method for the …

Hypoxia-induced stroke tolerance in the mouse is mediated by erythropoietin

K Prass, A Scharff, K Ruscher, D Löwl, C Muselmann… - Stroke, 2003 - Am Heart Assoc
Background and Purpose—Cellular response to hypoxia is mainly controlled by hypoxia-
inducible factor 1 (HIF-1). The HIF-1 target gene erythropoietin (EPO) has been described as …

Tolerance against ischemic neuronal injury can be induced by volatile anesthetics and is inducible NO synthase dependent

KJ Kapinya, D Lowl, C Futterer, M Maurer, KF Waschke… - Stroke, 2002 - Am Heart Assoc
Background and Purpose—We tested whether volatile anesthetics induce neuroprotection
that is maintained for a prolonged time. Methods—Rats were pretreated for 3 hours with 1 …