Transforming X-ray detection with hybrid photon counting detectors

A Förster, S Brandstetter… - … Transactions of the …, 2019 - royalsocietypublishing.org
Hybrid photon counting (HPC) detectors have radically transformed basic research at
synchrotron light sources since 2006. They excel at X-ray diffraction applications in the …

Single-photon counting detectors for diffraction-limited light sources

E Fröjdh, A Bergamaschi, B Schmitt - Frontiers in Physics, 2024 - frontiersin.org
When first introduced, single-photon counting detectors reshaped crystallography at
synchrotrons. Their fast readout speed enabled, for example, shutter-less data collection …

Hybrid pixel photon counting X-ray detectors for synchrotron radiation

C Brönnimann, P Trüb - Synchrotron Light Sources and Free-Electron …, 2020 - Springer
Detectors operated in single-photon counting mode have radically transformed basic
research at synchrotron light sources since 2006. Hybrid photon counting (HPC) pixel …

Electron counting with direct electron detectors in MicroED

J Hattne, MTB Clabbers, MW Martynowycz, T Gonen - Structure, 2023 - cell.com
The combination of high sensitivity and rapid readout makes it possible for electron-counting
detectors to record cryogenic electron microscopy data faster and more accurately without …

Accurate high-resolution single-crystal diffraction data from a Pilatus3 X CdTe detector

L Krause, K Tolborg, TBE Grønbech… - Journal of Applied …, 2020 - journals.iucr.org
Hybrid photon-counting detectors are widely established at third-generation synchrotron
facilities and the specifications of the Pilatus3 X CdTe were quickly recognized as highly …

[HTML][HTML] Dead time model for X-ray photon counting detectors with retrigger capability

P Zambon - Nuclear Instruments and Methods in Physics Research …, 2021 - Elsevier
We developed an analytical dead time model able to correctly describe the behavior of X-ray
photon counting detectors equipped with retrigger capability, which allows the system to …

Assessment of the spectral performance of hybrid photon counting x‐ray detectors

P Trueb, P Zambon, C Broennimann - Medical physics, 2017 - Wiley Online Library
Purpose Hybrid Photon Counting (HPC) detectors profoundly improved x‐ray diffraction
experiments at third generation synchrotron facilities. Enabling the simultaneous …

[PDF][PDF] Picosecond pump–probe X-ray scattering at the Elettra SAXS beamline

M Burian, B Marmiroli, A Radeticchio… - Journal of …, 2020 - journals.iucr.org
A new setup for picosecond pump–probe X-ray scattering at the Austrian SAXS beamline at
Elettra-Sincrotrone Trieste is presented. A high-power/high-repetion-rate laser has been …

High-energy X-ray applications: current status and new opportunities

DŠ Jung, T Donath, O Magdysyuk, J Bednarcik - Powder Diffraction, 2017 - cambridge.org
Characterization of semi and noncrystalline materials, monitoring structural phase
transitions in situ, and obtaining structural information together with spatial distribution of the …

Application of advanced X-ray methods in life sciences

Z Sayers, B Avşar, E Cholak, I Karmous - Biochimica et Biophysica Acta …, 2017 - Elsevier
Background Synchrotron radiation (SR) sources provide diverse X-ray methods for the
investigation of structure–function relationships in biological macromolecules. Scope of …