Computation of electric field and thermal properties of 3-phase cable

KRK Rajagopala, KP Vittal… - … Electronics and Control), 2012 - telkomnika.uad.ac.id
In this paper the electric field distribution, potential distribution and temperature distribution
in a 3-phase underground cable in common ground enclosure is analyzed and presented …

Electromagnetic and thermal analysis of high voltage three-phase underground cables using finite element method

S Conti, E Dilettoso, SA Rizzo - 2018 IEEE International …, 2018 - ieeexplore.ieee.org
In this paper a three core high-voltage underground cable used for urban power networks is
analyzed by means of Finite Element Method. The electrical analysis is performed in order to …

Analysis of the low frequency shielding behavior of high voltage cables in electric vehicles

K Feldhues, M Diebig, S Frei - 2014 International Symposium …, 2014 - ieeexplore.ieee.org
In this paper the low frequency shielding behavior of shielded high voltage cables for
electric vehicles is analyzed using analytical methods. First the basic theory on the …

Skin effect and proximity effect in a real, high voltage, double three-phase system

MA Prša, KK Kasaš-Lažetić… - 2011 IEEE EUROCON …, 2011 - ieeexplore.ieee.org
Both skin effect and proximity effect increase losses in any conductor with time varying
current. In order to determine those extra losses in a real case of two three-phase systems …

The AC and DC resistance of metal shields in medium voltage XLPE cables

Y Liu, H Zhang, J Chen - 22nd International Symposium on …, 2021 - ieeexplore.ieee.org
There is no universally accepted calculation and measuring methods for alternating current
(AC) resistance of metal shields in medium voltage (MV) crosslinked polyethylene (XLPE) …

[PDF][PDF] Gubici usled struja indukovanim u čeličnim cevima zakopanim ispod dalekovoda

N Mučalica, T Papić, K Kasaš-Lažetić… - … energetike, razvoja i … - researchgate.net
Provodne cevi za transport tečnosti i gasova su često zakopane u zemlji, u blizini
dalekovoda. Vremenski promenljivo magnetsko polje, prouzrokovano strujama u …

[PDF][PDF] Eddy Currents inside Pipeline buried beneath HV Overhead Power Transmission System

D Herceg, K Kasaš-Lažetić, D Kljajić, M Prša… - indel.etf.unibl.org
Conductive pipes for liquids and gas transportation are frequently buried in the ground, in
vicinity of a high voltage three-phase overhead electric power delivery system. The heating …

[PDF][PDF] Uticaj trofaznih visokonaponskih nadzemnih vodova na provodne cevi u neposrednoj blizini

N Mučalica, M Prša, K Kasaš-Lažetić - infoteh.etf.ues.rs.ba
Sadržaj—Provodne cevi za prenos tečnosti ili gasova se često ukopavaju u zemlju i mogu
da se nađu u blizini visokonaponskih trofaznih sistema. Vremenski promenljivo magnetsko …