A comparative analysis of methods for evaluation of ECG signal quality after compression

A Němcová, R Smíšek, L Maršánová… - BioMed research …, 2018 - Wiley Online Library
The assessment of ECG signal quality after compression is an essential part of the
compression process. Compression facilitates the signal archiving, speeds up signal …

Design and application of mobile embedded systems for home care applications

M Penhaker, M Stankus, J Kijonka… - 2010 Second …, 2010 - ieeexplore.ieee.org
Applied biotelemetry is of growing importance in today's world. Specificity of biotelemetric
data put special requirements on real biotelemetric system. This article describes some of …

[PDF][PDF] 663. Devices for position detection

D Vybiral, M Augustynek, M Penhaker - Journal of Vibroengineering, 2011 - core.ac.uk
The work deals with design and implementation of a wireless device for position sensing.
Part of this work is concerned with the analysis of the measurements. This study also …

Detection of ECG significant waves for biventricular pacing treatment

A Martin, P Jakub, P Marek… - 2010 Second International …, 2010 - ieeexplore.ieee.org
This paper is engaged in region of valid ECG signal processing, so the algorithm
development of the QRS complex's assignation from twelve lead surface ECG record …

Notice of Retraction: Controlling Peacemakers by Accelerometers

M Augustynek, M Penhaker… - … Conference on Computer …, 2010 - ieeexplore.ieee.org
Presently is used for controlling pacemakers measuring by one vibration sensor or a
movement sensor, which is placed on a pacemaker's case or on a tip of stimulating …

Measurement and calculation of cerebrospinal fluid in proportion to the skull

R Pustkova, F Kutalek, M Penhaker… - 9th RoEduNet IEEE …, 2010 - ieeexplore.ieee.org
The aim of this work was to create a method of an image data extracting to measure the
intracranial fluids. This method can be used in medical practice for an exact diagnosis and a …

Automatic ranking of eye movement in electrooculographic records

M Penhaker, T Štula, M Cerny - 2010 Second International …, 2010 - ieeexplore.ieee.org
The goal of the work is eye movement analysis in electrooculographic records. This analysis
can be used as supplement method of EEG for variant neurological diseases diagnosis …

Continuous noninvasive blood pressure measurement by near infra red CCD camera and pulse transmit time systems

P Zurek, O Krejcar, M Penhaker… - 2010 Second …, 2010 - ieeexplore.ieee.org
The need of continuous blood pressure measurement is usable in wide spectrum of
applications from physicians practice to home care applications. Many types of blood …

Long-term heart rate variability assessment

M Penhaker, T Stula, M Augustynek - … 2011: (BIOMED 2011) 20-23 June …, 2011 - Springer
Heart rate variability is good diagnostics method not only in cardiology investigation. This
kind of investigation is made in long term ECG analysis of Holter's type of examination. This …

Measurement and diagnosis assessment of plethysmographycal record

M Augustynek, M Penhaker, J Semkovic… - 5th Kuala Lumpur …, 2011 - Springer
Nowadays the plethysmography record evaluation is standard non-invasive method for
vessels condition appreciation (US) used in angiology and occupational therapy. The goal …