Review of performance testing of high precision reducers for industrial robots

Z Qiu, J Xue - Measurement, 2021 - Elsevier
The performance of a high precision reducer determines the accuracy and efficiency of the
mechanical motion, particularly in the field of industrial robots. To meet the requirements of …

[HTML][HTML] A review of automation of laser optics alignment with a focus on machine learning applications

I Rakhmatulin, D Risbridger, RM Carter… - Optics and Lasers in …, 2024 - Elsevier
In industrial and laboratory-based laser systems there are complicated processes involved
in the positioning of various optical components and these processes are time consuming …

High-precision measurement of the x-ray Cu Kα spectrum

MH Mendenhall, A Henins, LT Hudson… - Journal of Physics B …, 2017 - iopscience.iop.org
The structure of the x-ray emission lines of the Cu ${\rm {K}}{\alpha} _ {} $ complex has been
remeasured on a newly commissioned instrument, in a manner directly traceable to the …

Research on the influence model of collimating lens aberrations in autocollimation system based on the ray-tracing method

J Shi, Y Li, D Zhang, H Xing, Z Tao… - IEEE Sensors Journal, 2022 - ieeexplore.ieee.org
An influence model of collimating lens aberrations in an autocollimation system based on
the ray-tracing method is established. With the ray-tracing method, this model can accurately …

Cube-corner autocollimator with expanded measurement range

R Li, M Zhou, I Konyakhin, K Di, Y Lu, J Guo, Y Liu - Optics express, 2019 - opg.optica.org
A cube-corner is employed as a photoelectric autocollimator's reflector to extend the angle
measurement range and the corresponding algorithms are deduced. Experimental …

Test of the equivalence principle with chiral masses using a rotating torsion pendulum

L Zhu, Q Liu, HH Zhao, QL Gong, SQ Yang, P Luo… - Physical Review Letters, 2018 - APS
Here we present a new test of the equivalence principle designed to search for the possible
violation of gravitational parity using test bodies with different chiralities. The test bodies are …

[HTML][HTML] The lattice spacing variability of intrinsic float-zone silicon

EG Kessler, CI Szabo, JP Cline, A Henins… - Journal of Research …, 2017 - ncbi.nlm.nih.gov
Precision lattice spacing comparison measurements at the National Institute of Standards
and Technology (NIST) provide traceability of X-ray wavelength and powder diffraction …

A novel method of angular positioning error analysis of rotary stages based on the Abbe principle

YT Li, KC Fan - Proceedings of the Institution of Mechanical …, 2018 - journals.sagepub.com
Abbe error is the inherent systematic error in linear displacement measurement due to the
measuring axis being out of line with the moving axis. The resulting gap is called the Abbe …

The NIST silicon lattice comparator upgrade

MH Mendenhall, JP Cline, CI Szabo… - Review of Scientific …, 2023 - pubs.aip.org
The NIST silicon lattice comparator has been in service, in various forms, since the 1970s. It
is capable of measuring the difference in lattice spacing between specimens of high-quality …

Improving the angle measurement accuracy of circular grating

G Chen - Review of Scientific Instruments, 2020 - pubs.aip.org
Circular grating usually served as the angle displacement feedback element in a precision
turntable, and its measurement accuracy is very important. Installation errors always exist in …