State-of-the-art recent developments of large magnetorheological (MR) dampers: a review

M Abdul Aziz, SM Mohtasim, R Ahammed - Korea-Australia Rheology …, 2022 - Springer
Large MR (MR) dampers are popular due to their higher damping force capabilities which
makes them suitable in the field of civil engineering, structural engineering, suspension …

A review on vibration control strategies using magnetorheological materials actuators: Application perspective

A Masa'id, BW Lenggana, U Ubaidillah, DD Susilo… - Actuators, 2023 - mdpi.com
Magnetorheological (MR) materials are a group of smart materials used in new technologies
with controlled reliability. The development of these materials is expanding, starting from MR …

Seismic structural control using magneto-rheological dampers: A decentralized interval type-2 fractional-order fuzzy PID controller optimized based on energy …

AA Zamani, S Etedali - ISA transactions, 2023 - Elsevier
In this paper, a combination of the interval type-2 fuzzy logic controller (IT2FLC) with the
fractional-order proportional–integral–derivative (FOPID) controller, namely optimal interval …

Research developments in adaptive intelligent vibration control of smart civil structures

MU Saeed, Z Sun, S Elias - Journal of Low Frequency Noise …, 2022 - journals.sagepub.com
Control algorithms are the most critical aspects in the successful control of civil structures
subjected to earthquake and wind forces. In recent years, adaptive intelligent control …

Improving semi-active vibration control of an 11-story structure with non-linear behavior and floating fuzzy logic algorithm

A Bathaei, SM Zahrai - Structures, 2022 - Elsevier
In recent years, vibration control of structures subjected to the wind, earthquakes and traffic
loads has been broadly studied. Based on this, different types of dampers and control …

Vibration control of structure by optimising the placement of semi-active dampers and fuzzy logic controllers

K Takin, R Doroudi, S Doroudi - Australian Journal of Structural …, 2021 - Taylor & Francis
This study concentrates on applying semi-active dampers to control structures. In this paper,
fuzzy algorithm types 1 and 2 have been used as controllers to evaluate the voltage of semi …

Vibration control of suspension bridge due to vertical ground motions

SHH Lavasani, H Alizadeh… - Advances in …, 2020 - journals.sagepub.com
Suspension bridges due to their long span can experience large displacement response
under dynamic loading like earthquakes. Unlike other structures, their vertical vibration may …

Obtaining mass normalized mode shapes of motorway bridges based on the effect of traffic movement

M Sheibani, AK Ghorbani-Tanha - Structures, 2021 - Elsevier
Ambient vibration testing has become a promising alternative for the forced vibration method
due to its well-established practical advantages on bridge structures. However, because of …

Effect of Time Delay on Semi-Active Seismic Control of a Nonlinear 11-Story Building Using Floating and Predictive Fuzzy Logic Algorithm

A Bathaei, SM Zahrai - Journal of Civil Engineering and …, 2024 - xpublication.com
In control systems where sensors and receivers of sensor recorded data are used, there is a
possibility of time delay in transferring recorded data of structural motion, which is a factor to …

statistical performance of semi-active controlled 10-storey linear building using mr damper under earthquake motions

M Fahimi Farzam, B Alinejad… - Amirkabir Journal of …, 2021 - ceej.aut.ac.ir
Due to the advantages of semi-active control methods over passive and active methods, the
development and performance of these methods to control the structural response under …