Separate sensible and latent cooling technologies: A comprehensive review

OM Zaki, RH Mohammed, O Abdelaziz - Energy Conversion and …, 2022 - Elsevier
Conventional air conditioning (AC) systems provide simultaneous sensible and latent
cooling. This requires air to be cooled below its dew point temperature resulting in low …

Hybrid cooling systems: A review and an optimized selection scheme

F Kojok, F Fardoun, R Younes, R Outbib - Renewable and Sustainable …, 2016 - Elsevier
The hybrid cooling system has proved to be an energy saving technology for building air
conditioning. Numerous systems combining different cooling processes or cooling machines …

Working fluids selection and parametric optimization of an Organic Rankine Cycle coupled Vapor Compression Cycle (ORC-VCC) for air conditioning using low grade …

MT Nasir, KC Kim - Energy and Buildings, 2016 - Elsevier
This paper presents the thermal performance of several combinations of working fluids in the
Organic Rankine Cycle (ORC) powered Vapor Compression Cycle (VCC), for the domestic …

Performance analysis of a novel dual-evaporation-temperature combined-effect absorption chiller for temperature and humidity independent control air-conditioning

F Zhang, Y Yin, B Cao, Y Wang - Energy Conversion and Management, 2022 - Elsevier
Temperature and humidity independent control (THIC) air-conditioning (AC) systems are
promising alternatives to conventional AC systems. A novel dual-evaporation-temperature …

Generalization of second law efficiency for next-generation cooling and dehumidification systems

Z Lu, AJ Fix, DM Warsinger, JE Braun… - Energy Conversion and …, 2024 - Elsevier
Dehumidification plays a significant role in space conditioning energy use. Conventional
vapor compression cooling systems employ dewpoint condensation to deal with latent …

Energy impact of vacuum-based membrane dehumidification in building air-conditioning applications

HJ Cho, SY Cheon, JW Jeong - Applied Thermal Engineering, 2021 - Elsevier
The energy and operating performances of a vacuum membrane dehumidification system
were theoretically investigated for building air conditioning applications. The …

Multi-objective optimisation of building form, envelope and cooling system for improved building energy performance

KW Chen, P Janssen, A Schlueter - Automation in construction, 2018 - Elsevier
This research integrates cooling systems as a variable in the multi-objective optimisation of
building form and envelope design in the early design stages. The integration is achieved by …

Performance assessment and multi objective optimization of an Organic Rankine Cycle driven cooling air conditioning system

MT Nasir, MA Ali, TS Khan, E Al-Hajri, MB Kadri… - Energy and …, 2019 - Elsevier
Present work aims to investigate the thermal performance assessment of different
combinations of working fluids for an Organic Rankine Cycle powered Vapor Compression …

Separate sensible and latent cooling: Carnot limits and system taxonomy

KR Gluesenkamp, K Nawaz - International Journal of Refrigeration, 2021 - Elsevier
Energy efficiency and thermal comfort can be improved by independent control of
temperature and humidity. In recent work, an emerging class of cooling systems known as …

Performance analysis and optimization of a coupled open and close liquid desiccant sorption system using LiCl solution

X Cheng, Y Yin - Applied Thermal Engineering, 2023 - Elsevier
The efficient utilization of low-grade heat for air conditioning has been a topic of world
concern, especially for low-grade heat below 80℃. In this study, a novel coupled open and …